نوع مقاله : علمی - پژوهشی
عنوان مقاله English
نویسندگان English
Cellular core geometry is one of the factors influencing the stability and mechanical response of buckling-restrained braces. In this study, the effects of auxetic cell radius and arm length on the behavior of a brace incorporating a lattice core were investigated using the finite element method in ABAQUS. The inherent stability of the core was assessed through linear elastic eigenvalue buckling analysis without the restraining assembly, while the mechanical response of the brace was examined through nonlinear analysis under monotonic tensile and compressive loading. To assess the modeling approach, the response of a reference specimen with a slotted core was compared with previously reported experimental and numerical results. The results showed that, at a constant arm length of 40 mm, increasing the cell radius from 20 to 25 mm increased the first-mode buckling load of the core from 1.58 to 1.69 kN; however, a further increase in radius to 30 mm reduced this value to 1.25 kN. Furthermore, at a constant cell radius of 25 mm, increasing the arm length from 40 to 70 mm reduced the first-mode buckling load from 1.69 to 1.06 kN. Specimen BRB-R25L40 exhibited the highest tensile and compressive load-carrying capacities, reaching 2.89 and 1.78 kN, respectively, whereas specimen BRB-R25L60 exhibited the largest displacements at peak load in both tension and compression. Within the range of configurations investigated, the selection of a suitable specimen depends on whether priority is given to load-carrying capacity, core stability, or displacement at peak load.
کلیدواژهها English