Determination of Response Modification Factor of the RC frame retrofitted with the linked column frame system

Document Type : Original Article

Authors

1 Faculty of Civil Engineering, Semnan University, Semnan, Iran,

2 Professor, Faculty of Civil Engineering, Semnan University, Semnan, Iran

3 Associate Professor, Faculty of Civil Engineering, Semnan University, Semnan, Iran

Abstract

The adequate solution for protecting main structural members and reducing the destructive effects of earthquakes use of structural systems combined with the replaceable fuse members, which due to the ductile behavior and seismic energy dissipation are next to the main members of the structure. Relatively low cost and easy repair process in these systems leads to rapid return to occupancy after an earthquake. In this study presents the response modification factor ‘R’ of the RC frame retrofitted with the linked column frame system with the number of floors 3- and 6-story with three different lengths of link beam. Based on the results of modeling the force-displacement curve, the R factor and related parameters are calculated based on the equivalent energy method. The results of the nonlinear static analysis, using the linked column frame system for retrofitting RC frame Can be increased the load bearing capacity and the capability of absorption and dissipation energy than a model of the RC frame without retrofitting about 3.5 times. The R factor in the Limit state method is about 8.95 which is more about 71% than a model of the RC frame without retrofitting. Also, the distance the corresponding displacement for the first plastic hinges formed in link beam and the corresponding displacement for the first plastic hinge formed in the RC frame for the model of LCF-0.8-0.45 is more than other models. This causes the damage to the replaceable link beam and the main structure is remained elastic phase and at a high risk level, this system will achieve to reach the rapid return to occupancy performance level.

Keywords


[1] Applied Technology Council, (1996). Seismic evaluation and retrofit of concrete buildings. ATC- 40 report, Redwood City, California.
[2] Building Seismic Safety Council (2000). Prestandard and commentary for the seismic rehabilitation of buildings. Report FEMA-356, Federal Emergency Management Agency, Washington, D.C.
[3] Kheyroddin, A. and Sharbatdar, M.K. (2016). Strengthening of R.C. structures with Steel Plate and FRP Composites. Semnan: Semnan University, Page. 552.
 [4] Dusicka P. and Iwai R. (2007). Development of Linked Column Frame System for Seismic Lateral Loads. In Structural Engineering Research Frontiers, pp. 1–13.
[5] Dusicka, P. and Lewis, G. (2010). Investigation of replaceable sacrificial steel links. Proceedings of the 9th U.S. National and 10th Canadian Conference on Earthquake Engineering, number 1659. EERI.
[6] Nader M, Baker G, Duxbury J and Maroney B. (2000). Seismic design for the self-anchored suspension bridge–san Francisco Oakland bay bridge. 30th Street, Sacramento, CA 95816.
[7] Roeder C. W. and Popov E. P. (1977). Inelastic behavior of eccentrically braced steel frames under cyclic loadings. STI/Recon Tech. Rep. N, vol. 78, no. August, p. 20375.
[8] Pandikkadavath, M. S., and Sahoo, D. R. (2017). Mitigation of seismic drift response of braced frames using short yielding-core BRBs. Steel Comp. Structure., 23(3) 285-302
[9] Xu, Z.D., Dai, J. and Jiang, Q.W. (2018). Study on fatigue life and mechanical properties of BRBs with viscoelastic filler. Steel Comp. Struct., 26(2).
[10] Cahís, X., Simon, E., Piedrafita, D., Catalan, A. (2018). Core behavior and low-cycle fatigue estimation of the Perforated Core Buckling-Restrained Brace. Engineering Structures, vol (174), 126-138.
[11] Li, G.Q., Sun, Y.Z., Jiang, J., Sun, F.F., Ji, C. (2019). Experimental study on two-level yielding buckling-restrained braces. Journal of Constructional Steel Research, vol (159), 260-269.
[12] Wang Y., Ibarra L., Pantelides C. (2019). Collapse capacity of reinforced concrete skewed bridges retrofitted with buckling-restrained braces. Engineering Structures, 184, 99–114.
[13] Bedon, C., and Amadio, C. (2019). ADAS dampers for the hazard protection of multi-storey buildings with glazing envelopes: a feasibility study. Bollettino di Geofisica Teorica ed Applicata. Vol. 60, n. 2, pp. 197-220. DOI: 10.4430/bgta0253.
[14] Karami Mohammadi, R. Nasri, A., Ghaffary, A. (2017). TADAS dampers in very large deformations. International Journal of Steel Structures, 17(2): 515-524. DOI 10.1007/s13296-017-6011-y.
[15] Ghaffary, A., Karami Mohammadi, R. (2016). Framework for virtual hybrid simulation of TADAS frames using opensees and abaqus. Journal of Vibration and Control, vol (24), n. 11, pp 2165-2179, https://doi.org/10.1177/1077546316679029.
[16] TahamouliRoudsari M., Eslamimanesh M.B., Entezari A.R., Noori O., Torkaman M. (2018). Experimental Assessment of Retrofitting RC Moment Resisting Frames with ADAS and TADAS Yielding Dampers. Structures, vol, 14, pp 75-87, DOI:10.1016/j.istruc.2018.02.005.
[17] Rahnavard, R., Hassanipour, A., Suleiman, M., Mokhtari, A. (2017). Evaluation on eccentrically braced frame with single and double shear panels. Journal of Building Engineering, vol (10), pp 13-25.  
[18] Malakoutian M, Berman JW, Dusicka P. (2013). Seismic response evaluation of the linked column frame system. Earthq Eng Struct Dyn, 42:795–814.
[19] Malakoutian M, Berman J.W, Dusicka P, Lopes A. (2016). Quantification of Linked Column Frame Seismic Performance Factors for Use in Seismic Design. Journal of Earthquake Engineer; 20:535–58. DOI:10.1080/13632469.2015.1104750.
[20] Shen Y., Christopoulos C., Mansour Nabil, Tremblay R. (2011). Seismic design and performance of steel moment-resisting frames with nonlinear replaceable links. · Journal of Structural Engineering, vol (137), No. 10, pp1107–1117, DOI: 10.1061/ (ASCE) ST.1943-541X.0000359
[21] Shoeibi, S., Kafi, M.A., Gholhaki, M. (2017). New performance-based seismic design method for structures with structural fuse system. Engineering Structures, 745–760.
[22] Lia, Y.W., Lib, G.Q., Jiangc J., Sun F.F. (2018). Mitigating seismic response of RC moment resisting frames using steel energy-dissipative columns. Engineering Structures 174, 586–600.
[23] Choi, I.R. and Park, H.G. (2011). Cyclic loading test for reinforced concrete frame with thin steel infill plate. Journal of Structural Engineering, 137(6), pp.654-664.
[24] Choi, I.R. and Park, H.G. (2008). Cyclic Test for Framed Steel Plate Walls With Various Infill Plate Details. The 14th World Conference on Earthquake Engineering.
[25] Abaqus Analysis User's Guide (6.14-2).
[26] ACI Committee 318 (2014). Building Code Requirements for Structural Concrete and Commentary (ACI 318 R-14). American Concrete Institute: Farmington Hills, MI, USA.
[27] Tasnimi, A. A. and Masoumi, A. (2006). Estimation of Response Modification Factors for RC-MRF Structures. Building and Housing Research Center, R-436.
[28] ATC-19 (1995). Structural Response Modification Factors. Applied Technology Council, Redwood City, California, 5–32
[29] Krawinkler, H., and Nassar, A. A. (1992). Seismic design based on ductility and cumulative damage demands and capacities. Nonlinear seismic analysis and design of reinforced concretebuildings, P. Fajfar and H. Krawinkler, Elsevier Applied Science.London and New York, pp. 23-29.
[30] Miranda, E. and Bertero, V.V. (1994). Evaluation of strength reduction factors for earthquake-resistant design. Earthquake spectra, 10(2), pp.357-379
[31] Newmark, N.M. and Hall, W.J. (1982). Earthquake spectra and design. Berkeley, California Earthquake Engineering Research Inst
[32] IBC (2018). International Building Code. International Conference of Building Officials, Whittier, CA.
[33] ATC-40 (1996). Seismic Evaluation and Retrofit of Reinforced Concrete Buildings. Applied Technology Council.
[34] FEMA-356 (2000).Prestandard and Commentary for the Seismic Rehabilitation of Buildings. American Society of Civil Engineers.
[34] Kim J., Choi. (2006). Displacement-Based Design of Supplemental Dampers for Seismic Retrofit of a Framed Structure. Journal of Structural Engineering © ASCE, Vol. 132, No. 6, June 1. DOI: 10.1061/ASCE0733-9445.