Evaluation of nonlinear behavior of High Performance Fiber Reinforced Cementitious Composite (HPFRCC) Frames

Document Type : Original Article

Authors

Department of Civil Engineering, Semnan Branch, Islamic Azad University, Semnan, Iran

Abstract

Replacing of conventional concrete by High Performance Fiber Reinforced Cementitious Composite (HPFRCC) could improve tensile strength, bending strength, shear strength and other capability of behaviour such as ductility, energy absorption and toughness. Strain hardening behaviour in (HPFRCC) could result in restrict of crack and prevent from crack widening. Also, because of the high strain capacity of (HPFRCC), using this material in the beam-column connection is more attention paid by researchers. After verification of numerical models for frame using OPENSEES software and comparison with experimental results, two 2D frames with 3 and 6 stories has been created to study. These frames have been designed based on ACI 318. Each frame is considered in 4 formats containing conventional concrete in all elements (RC), containing of (HPFRCC) in beam-column connection (RCH1), containing of (HPFRCC) in beam-column connection and first story column base (RCH2) and containing of (HPFRCC) in all elements. Results from nonlinear static analysis (pushover analysis) show increase of lateral strength, ductility and ultimate displacement of frames containing (HPFRCC) with respect to (RC) frames. Also, using of (HPFRCC) in frames has been decreased maximum story drift ratio, maximum roof displacement and has been increased maximum base shear and story shear in nonlinear time history analysis.

Keywords

Main Subjects


[1] Naaman, A. E. (2008). High performance fiber reinforced cement composites. Singapore: World
Scientific, 91-153.
[2] Hemmati, A. Kheyroddin, A. Sharbatdar, M. Park, Y. and Abolmaali, A. (2016). Ductile behavior of
high performance fiber reinforced cementitious composite (HPFRCC) frames. Construction and
Building Materials, 115, 681-689.
[3] Zhang, R. Matsumoto, K. Hirata, T. Ishizeki,Y. Niwa, J. (2015). Application of PP-ECC in beam–
column joint connections of rigid-framed railway bridges to reduce transverse reinforcements.
Engineering Structures, 86, 146-156.
[4] Chidambaram, R.S. and P. Agarwal. (2015). Seismic behavior of hybrid fiber reinforced cementitious
composite beam–column joints. Materials & Design, 86, 771-781.
[5] Said, S.H. and H.A. Razak. (2016). Structural behavior of RC engineered cementitious composite
(ECC) exterior beam–column joints under reversed cyclic loading. Construction and Building Materials,
107, 226-234.
[6] Saghafi, MH. Shariatmadar, H. Kheyroddin, A. (2017). Experimental Evaluation of Mechanical
Properties of High Performance Fiber Reinforced Cementitious Composites. Concrete Research, 9(2),
29-42.
[7] Saghafi, MH. Shariatmadar, H. (2018). Structural behavior of RC High performance fiber reinforced
cement composites (HPFRCC) exterior beam–column joints under reversed cyclic loading. Concrete
Research, Available at URL: 12 March 2018.
[8] McKenna, F. and G.L. Fenves. (2007). The OpenSees command language manual. University of
California, Berkeley (opensees. ce. berkeley. edu).
[9] Han, T. S. Feenstra, P. H. and Billington, S. L. (2003). Simulation of highly ductile fiber-reinforced
cement-based composite components under cyclic loading. Structural Journal, 100(6), 749-757.
[10] ACI Standards. (2011)., Building Code Requirements for Structural Concrete (ACI 318-11M) and
Commentary, Michigan: American Concrete Institute, 107-196.
[11] Iranian Code of Practice for Seismic Resistant Design of Buildings. (2005)., Standard, No. 2800 .Third
Edition., Tehran: Building and Housing Research Center, 14-31.
[12] Structural Engineering Institute. (2005)., Minimum design loads for buildings and other structures,
Virginia: American Society of Civil Engineers, 5-6.
[13] Paulay, T. and M.N. Priestley. (1992). Seismic design of reinforced concrete and masonry buildings.
NewYork:Wiley