[1] A. Whittaker, M. Constantinou, Fluid viscous dampers for building construction, in: First International Symposium on Passive Control, 2000, pp. 133-142.
[2] E. Martinez-Romero, Experiences on the use of supplementary energy dissipators on building structures, Earthquake Spectra, 9(3) (1993) 581-625.
[3] G. Dargush, T. Soong, Behavior of metallic plate dampers in seismic passive energy dissipation systems, Earthquake Spectra, 11(4) (1995) 545-568.
[4] R.B. Fleischman, A. Sumer, X. Li, Development of modular connections for steel special moment frames, in: Structures 2004: Building on the Past, Securing the Future, 2004, pp. 1-9.
[5] A. Sumer, Y. Pan, G. Wan, R.B. Fleischman, Development of modular connections for steel special moment frames, in: Proc. 13th. World Conf. on Earthquake Engineering, 2004.
[6] K. Kasai, M. Nakai, Y. Nakamura, H. Asai, Y. Suzuki, M. Ishii, Current status of building passive control in Japan, in: The 14th world conference on earthquake engineering, Beijing, China Google Scholar, 2008.
[7] H.-N. Li, G. Li, Earthquake-resistant design of RC frame with “dual functions” metallic dampers, in: ASME 2007 Pressure Vessels and Piping Conference, American Society of Mechanical Engineers, 2007, pp. 43-53.
[8] S.Bagheri,M.Barghian,F.Sayeri,Heightwise distribution of stiffness ratio for optimum seismic design of steel frames with metallic-yielding dampers,”, In 6th International Conference on Seismology and Earthquake Engineering, International Institute of Seismology and Earthquake Engineering, 2011, (in Persian).
[9] C. Tsai, K. Tsai, TPEA device as seismic damper for high-rise buildings, Journal of engineering mechanics, 121(10) (1995) 1075-1081.
[10] K.-C. Tsai, C. Li, Seismic Analysis of Passive Energy Dissipation Subsystems by Hybrid Experiments, in: Proceedings of the 12th International Modal Analysis, 1994, pp. 1520.
[11] S. Kherad, Designing a central piece with absorbent energy and repaired for Short to Medium-Order Regular Buildings, the south branch of Islamic Azad University of Tehran, 2012, (in Persian).
[12] Guideline and Details for Seismic Rehabilitation of Existent Building , Strategic Oversight Deputy Executive Office, 2010.
[13] K.-C. Tsai, H.-W. Chen, C.-P. Hong, Y.-F. Su, Design of steel triangular plate energy absorbers for seismic-resistant construction, Earthquake spectra, 9(3) (1993) 505-528.
[14] R. Karami Mohammadi, M.R. Garoosi, OPTIMUM DISTRIBUTION OF TADAS DAMPERS FOR IMPROVING THE SEISMIC PERFORMANCE OF MOMENT FRAMES, Sharif Journal of Civil Engineering, 32.2(3.2) (2016) 117-123.
[15] Poursha M, Khoshnoudian F, Moghadam AS. A consecutive modal pushover procedure for estimating the seismic demands of tall buildings. Engineering Structures. 2009 Feb 1;31(2):591-9.
[16]Standard No.2800-05. “Iranian code of practice for seismic resistant design of buildings.” 4th edition., Building and Housing Research Center, BHRC publication, Tehran, Iran (2013).
[17] Quantification of building seismic performance factors. FEMA P695, Federal Emergency Management Agency, Washington, DC, June 2009.