Journal of Structural and Construction Engineering

Journal of Structural and Construction Engineering

Experimental Study on the Effect of Opening Vertical Distance from the Horizontal Runner on the Seismic Performance of Gypsum-Sheathed Cold-Formed Steel Frames

Document Type : Original Article

Authors
1 Ph. D candidate, Department of Civil Engineering, Taft. C., Islamic Azad University, Taft, Iran
2 Professor, School of Civil and Environmental Engineering, The University of New South Wales, Sydney, Australia
3 Faculty Member,Department of Civil Engineering, Taft. C., Islamic Azad University, Taft, Iran
Abstract
This study experimentally investigates the effect of the vertical distance of openings from the horizontal runner on the seismic performance of cold-formed steel (CFS) walls sheathed with gypsum boards. Two full-scale frame types, each measuring 2400 × 2400 mm and containing a single 1200 × 1200 mm opening, were designed and constructed. In Frame A, the opening was positioned 300 mm from the top runner, while in Frame B this distance was set at 400 mm. To ensure the accuracy and repeatability of the results, three specimens of each frame type were tested under cyclic loading in accordance with ASTM E2126-07. The experimental results revealed that reducing the vertical distance of the opening from the horizontal runner directly improves the lateral resistance of the walls. Specifically, the average ultimate lateral resistance was measured at 4.82KN for Frame A and 3.84 KN for Frame B, indicating a 20–25% reduction in resistance when the opening was placed farther from the runner. In contrast, the ultimate displacement remained nearly constant at approximately 48 mm for both frame types, demonstrating that the position of the opening has little influence on the displacement capacity of the system. Furthermore, the observed failure modes indicated that in Frame A, failure initiated at larger displacements, and the screws around the opening detached later compared to Frame B, suggesting a more favorable stress distribution and improved connection performance in this configuration.
Keywords

Subjects


[1].  ASTM E2126-07, ASTM International. (2007). Standard Test Methods for Cyclic (Reversed) Load Test for Shear Resistance of Vertical Elements of the Lateral Force Resisting Systems for Buildings. West Conshohocken, PA, USA.
[2].  Vieira, L.C.M., Schafer, B.W. (2010). Behavior and Design of Cold-Formed Steel Wall Studs. Journal of Constructional Steel Research, Vol. 66, No. 8–9, pp. 1116–1127.
[3].  Vieira, L.C.M., Schafer, B.W. (2013). Cold-Formed Steel Framed Shear Walls: Sheathing Braced Design Methodology. Thin-Walled Structures, Vol. 67, pp. 78–92.
[4].  Adham, M., LaBoube, R.A., Yu, W.W. (1990). Behavior of Cold-Formed Steel Wall Studs with Openings. Final Report, University of Missouri–Rolla.
[5].  Yu, C., Chen, Y., Schafer, B.W. (2014). Simulation of Cold-Formed Steel Framed Shear Walls with Openings. Thin-Walled Structures, Vol. 84, pp. 406–419.
[6].  Fiorino, L., Macillo, V., Landolfo, R. (2016). Seismic Behavior of Sheathed Cold-Formed Steel Structures: A Review. Thin-Walled Structures, Vol. 106, pp. 202–222.
[7].  Moghimi, H., Ronagh, H.R. (2018). Behavior of Cold-Formed Steel Shear Walls with Openings under Seismic Loading. Journal of Constructional Steel Research, Vol. 144, pp. 55–68.
[8].  National Instruments. LabVIEW Signal Express User Manual. National Instruments Corporation, Austin, Texas, USA, 2007.
[9].  Peterman, K. D., & Schafer, B. W. (2014). Hysteretic Response of Cold-Formed Steel Framed Shear Walls with Sheathing. Thin-Walled Structures, 79, 173–184
[10].          Yu, W., & Zhao, X. (2018). Numerical Study on the Seismic Performance of Cold-Formed Steel Shear Walls with Openings. Journal of Constructional Steel Research, 150, 1–12.
[11].          Moghimi, H., & Ronagh, H. R. (2019). Experimental Study of Cold-Formed Steel Shear Walls with Gypsum Sheathing under Cyclic Loading. Thin-Walled Structures, 141, 351–362.

  • Receive Date 14 August 2025
  • Revise Date 19 October 2025
  • Accept Date 13 November 2025