Investigate effects of the core distance from confining concrete on behavior of buckling restrained braces

Document Type : Original Article

Authors

1 Associate Professor, Department of Civil Engineering, University of Semnan, Semnan, Iran

2 MSc of Structural Engineering, Department of Civil Engineering, University of Semnan, Semnan, Iran

3 Assistant Professor, Civil Engineering Department, University of Semnan, Semnan, Iran

Abstract

Due to disadvantages of seismic behavior in conventional braces in term of low plasticity and asymmetric hysteresis curve in tension and compression and pinching which reduces the energy dissipation rate, Buckling Restrained Braces (BRBs) have been proposed as a new generation of bracing system. This paper examines specific type of these braces with steel core and concrete sheath. The effects of core distancefrom confining concrete of these braces haven been discussed using Finite element analysis method. The results show that buckling mode and energy absorption of this system have largely depend on the distance, and 2 to 4 mm distance causes the most energy dissipation.

Keywords

Main Subjects


[1] Dolce M. Cardone D. and Marnetto R. (2000) Implementation and testing of passive control devices based on shape memory alloys. Earthquake Engineering and Structural Dynamics, 29, 945-68.
[2] Kumar G.R. Kumar S.R. and Kalyanaraman V. (2007) Behavior of frames with Non-Buckling bracings under earthquake loading. Journal of constructional steel research, 63, 254-262.
[3] Analysis Users Manual, "Volume1:Introduction, Spatial  Modeling Execution & Out put",Simulia.
[4] Black, C. J., Markis, N., and Aiken, I., (2002), "Component testing, stability analysis and
characterization of Buckling-Restrained Unbonded Braces ", Technical Rep. No. PEER Report
2002/8, Pacific Earthquake Engineering Research Center, Univ. of California at Berkeley,
Berkeley, Calif.
[5] Markis, N., (2002), "Plastic torsional buckling of a cruciform column ", J. Engrg. Mech. ASCE.
Inreview.
[6] Lopez, W. A., Gwie, D. S., Saunders, C. M., Lauck, T.W., (2002), "Lessons learned from largescale
tests of unbonded braced frame subassemblages ", Proceedings 71st Annual Convention,
Structural Engineers Association of California, Sacramento, California.
[7] Fahnestock, L. A., Sause, R., and Ricles, J. M., (2006), "Seismic response and performance of
buckling-restrained braced frames ", Journal of Structural Engineering, ASCE, September 2007,
pp. 1195-1204.
[8] N. Hoveidae and B. Rafezy (2012), "Overall buckling behavior of all-steel buckling restrained braces," Journal of Constructional Steel Research, no. 79, pp. 151-158.
[9] T. Takeuchi, J. F. Hajjar, R. Matsui, K. Nishimoto and I. D. Aiken (2012), "Effect of local buckling core plate restraint in buckling restrained braces," Engineering Structures, no. 44, pp. 304-311.
[10] Ahmad Mostafa.Abdulwahab (2013),"Nonliner Finite Element Modeling of The Load-Carrying and Energy Dissipationc Apacitice for Buckling-Restrained Brace", Sharjah, United Arab Emirates.
[11] A. Korzekwa & R. Tremblay (2009),"Numerical simulation of the cyclic inelastic behaviour of buckling
restrained braces",Taylor & Francis Group, London, ISBN 978-0-415-56326-0.
[12] Chou, C., Chen, S (2010). Subassemblage tests and finite element analyses of sandwiched buckling restrained braces, Engineering Structures, 32:8, 2108-2121.
[13] Tremblay, R., Bolduc, P., Neville, R., and DeVall(2006), R.Seismic testing and performance of buckling restrained bracing systems. Can. J. Civ. Eng. 33(1): 183-198.