Journal of Structural and Construction Engineering

Journal of Structural and Construction Engineering

Application of Strut-and-Tie Method for Shear Analysis of Deep ‎Beams ‎Reinforced with GFRP Bars: Model Development and ‎Experimental Validation

Document Type : Original Article

Authors
1 Postdoctoral Researcher, Faculty of Civil, Water, and Environmental Engineering, Shahid Beheshti University, Tehran, ‎Iran
2 PhD Graduated, Department of Civil Engineering, Sharif University of Technology, Tehran, Iran
3 Assistant Professor, Department of Civil Engineering, Shahid Beheshti University, Tehran, Iran
10.22065/jsce.2026.591552.4074
Abstract
Deep reinforced concrete beams with low shear span-to-effective depth ratio ‎‎(a/d) are considered ‎challenging structural members due to their load transfer ‎mechanism through arch action and ‎dominant shear behavior. Unlike slender ‎beams, the internal force distribution in deep beams is ‎highly nonlinear and ‎governed by compression struts and tension ties, which complicates both ‎‎analysis and design. Given the growing concerns regarding corrosion of steel ‎reinforcement in ‎aggressive environments, the use of glass fiber reinforced ‎polymer (GFRP) bars has emerged as a ‎promising alternative due to their ‎corrosion resistance, high tensile strength, and lightweight ‎characteristics. ‎However, fundamental differences in mechanical properties of GFRP ‎‎reinforcement, such as linear elastic behavior up to rupture, relatively low ‎modulus of elasticity, ‎and lack of yielding, necessitate revisions in conventional ‎design assumptions and analytical ‎models developed for steel-reinforced ‎concrete members. In this study, the shear behavior and ‎structural performance ‎of GFRP-reinforced concrete deep beams were investigated through a ‎‎comprehensive experimental program involving six full-scale specimens. The ‎experimental ‎variables included the a/d, levels of concrete compressive ‎strength, ‎the presence or absence of horizontal web reinforcement, and the size effect. The ‎results ‎demonstrated that the investigated parameters significantly influenced ‎the structural behavior of ‎the beams. Reducing the a/d ratio from 0.9 to 0.5 ‎increased the ultimate load capacity by ‎approximately 59%, confirming the ‎dominance of arching action in deep beams with shorter ‎shear spans. Increasing ‎the concrete compressive strength from 22 MPa to 45 MPa improved the ‎load ‎capacity by about 48%, while the inclusion of horizontal web reinforcement ‎enhanced the ‎load capacity by approximately 24% and contributed to improved ‎crack control. In addition, an ‎analytical model was developed and adapted for ‎GFRP-reinforced deep beams. The proposed ‎model produced prediction-to-test ‎ratios ranging from 0.56 to 1.17 for the tested specimens. ‎
Keywords
Subjects


Articles in Press, Accepted Manuscript
Available Online from 20 November 2026

  • Receive Date 29 August 2026
  • Revise Date 21 October 2026
  • Accept Date 20 November 2026