Journal of Structural and Construction Engineering

Journal of Structural and Construction Engineering

Geometry Optimization of Double Concave Friction Pendulum Bearings for Tall Buildings Using Response Surface Methodology with Limited Effective Period Elongation Compared with Conventional DCFP

Document Type : Original Article

Authors
1 PhD Candidate, Department of Civil Engineering, ST.C., Islamic Azad University, Tehran, IRAN
2 Assistant Professor, Department of Civil Engineering, ST.C., Islamic Azad University, Tehran, IRAN
3 Professor ,Department of Civil Engineering, ST.C., Islamic Azad University, Tehran, IRAN
10.22065/jsce.2026.593963.4092
Abstract
Although Double Concave Friction Pendulum (DCFP) bearings have been ‎widely investigated for seismic isolation of buildings, existing design ‎approaches mainly rely on predefined bearing configurations or isolated ‎optimization of individual parameters, while coordinated optimization of ‎geometric and frictional characteristics for tall buildings remains limited. ‎This study proposes an Optimized Double Concave Friction Pendulum (O-‎DCFP) through simultaneous optimization of sliding-surface curvature radii ‎and friction coefficients using an integrated Design of Experiments (DOE)–‎Response Surface Methodology (RSM) framework. Four design variables (R₁, ‎R₂, μ₁, and μ₂) were investigated using an 18-run I-optimal design. Each ‎configuration was evaluated by nonlinear response-history analyses of a 60-‎story steel benchmark building under eleven spectrum-compatible far-field ‎earthquake records, resulting in 198 nonlinear dynamic simulations. ‎Response surface models predicted four key response parameters: effective ‎structural period, structural plastic energy, maximum interstory drift ratio, ‎and peak floor acceleration. Desirability-based multi-objective optimization ‎identified the optimum O-DCFP configuration (R₁ = 610 mm, R₂ = 1000 mm, ‎μ₁ = 0.08, and μ₂ = 0.16), reducing the effective structural period by 4.0%, ‎mean structural plastic energy by 5.4%, maximum interstory drift ratio by ‎‎20.3%, and mean peak floor acceleration by 14.3% compared with a ‎conventional DCFP configuration. Independent nonlinear verification ‎analyses confirmed prediction errors below 4%, while application to 40- and ‎‎90-story buildings demonstrated consistent improvements without ‎recalibration, confirming transferability. The proposed DOE–RSM ‎framework provides an efficient methodology for performance-based ‎optimization of friction pendulum isolation systems with substantially lower ‎computational cost, demonstrating that coordinated optimization of sliding-‎surface geometry and frictional characteristics improves seismic ‎performance without relying solely on increasing the isolation period.‎
Keywords
Subjects


Articles in Press, Accepted Manuscript
Available Online from 03 September 2026

  • Receive Date 26 July 2026
  • Revise Date 27 August 2026
  • Accept Date 03 September 2026