Self-Compacting Concrete (SCC), owing to its ability to flow under its own weight and completely fill formwork without the need for mechanical vibration, plays a significant role in improving construction quality and reducing problems associated with inadequate compaction. However, the proper design of SCC, particularly at low water-to-cementitious materials ratios, requires simultaneous control of fresh properties and compressive strength. In this study, the behavior of silica fume-incorporated SCC was experimentally investigated, and a predictive model for compressive strength was subsequently developed using Gene Expression Programming (GEP). A total of 48 SCC mix designs were prepared based on the National SCC Mix Design Method, of which 46 mixtures satisfied the self-compacting criteria. The main variables included the water-to-cementitious materials ratio at four levels (0.35, 0.40, 0.45, and 0.50) and silica fume replacement at three levels (0%, 5%, and 10% by weight of cement). Fresh concrete properties were evaluated through slump flow, V-funnel, and visual stability index (VSI) tests, while compressive strength was measured at 7, 28, and 90 days. The results indicated that silica fume replacement up to 5% had no adverse effect on workability, whereas a 10% replacement level reduced flowability and increased superplasticizer demand. Furthermore, replacing 5% and 10% of cement with silica fume led to an average increase of 9.3% and 18.4%, respectively, in the 28-day compressive strength compared with the control mixtures. For compressive strength prediction, GEP was employed considering the key mix design parameters. The developed model achieved a coefficient of determination (R²) of approximately 0.90 and a root mean square error (RMSE) of 2.59 MPa, demonstrating satisfactory predictive performance and providing an explicit analytical equation suitable for engineering design applications.
Keywords
Subjects


Articles in Press, Accepted Manuscript
Available Online from 16 August 2026

  • Receive Date 21 April 2026
  • Revise Date 08 August 2026
  • Accept Date 16 August 2026