انجمن مهندسی سازه ایرانمهندسی سازه و ساخت2476-39778120210321Finite Element Analysis of Blind Bolted Extended and Flush End Plate Connections of Steel Beams to Hollow Section Columnsتحلیل اجزای محدود اتصالات پیچ کور ورقهای انتهایی توسعه یافته و هم تراز تیر فولادی به ستون با مقطع توخالی5228283610.22065/jsce.2019.165944.1754FAمحسن ایزدی نیااستادیار، گروه مهندسی عمران، واحد نجف آباد، دانشگاه آزاد اسلامی، نجفآباد، ایران0000-0002-9365-8295نیما ریاحیگروه مهندسی عمران، واحد نجف آباد، دانشگاه آزاد اسلامی، نجفآباد، ایرانJournal Article20190106Hollow structural sections (HSS) have been used in many structural applications, owing to their efficient structural performance and suitable appearance. However, due to the lack of access inside the HSS column for bolting purposes, it has been difficult to develop a practical bolted moment connection. Thus, field welded beam-to-HSS column connections have been the only viable method. Recently some blind fasteners are developed to be used in application which access for installation is only from one side of the connection. At the moment different blind bolts were designed for use in one side connections. In this project, comparison of the test result of an article and three dimensional finite element modeling of the blind bolted end plate joint with concrete-filled square hollow section columns to steel beam and Lindapter blind bolt (Hollo-Bolt) under monotonic loading indicates that the finite element analyses can be used to predict the connection behavior with sufficient accuracy. After that studied parametric investigation under cyclic loading into the end plates thickness, bolt diameter and bolt pretension force for the blind bolted extended and flush end plate connections of steel beams to hollow section column with ABAQUS and got moment-rotation hysteretic curve of each ones. Results have shown that the end plates thickness, bolt diameter and bolt pretension force have influenced on the connection behavior.اعضا با مقاطع توخالی HSS به خاطر عملکرد سازه ای و ظاهر مناسب در بسیاری از برنامه های سازه ای مورد استفاده قرار می گیرند. با این وجود به علت نبود دسترسی به داخل ستون HSS برای اهداف پیچ کردن، توسعه اتصالات خمشی کاربردی بسیار مشکل میباشد. بنابراین اتصالات تیرهای جوش داده شده به ستون HSS تنها روش ممکن بود. اخیراً برخی اتصال دهنده های کور به این منظور برای استفاده در اتصال شکل گرفته اند که در آن برنامه دسترسی برای نصب را فقط از یک طرف اتصال ممکن می سازند. در حال حاضر پیچ-های کور مختلفی جهت استفاده در اتصالات طراحی شده اند. در این مقاله مقایسه نتایج آزمایشگاهی مقاله ای با اتصال پیچ کور تیر فولادی به ستون مربعی پر شده با بتن توسط پیچ کور لینداپتر (Hollo-Bolt) تحت بارگذاری یک طرفه با مدل سازی اجزای محدود سه بعدی نشان داد که می توان از تجزیه و تحلیل اجزای محدود برای پیش بینی رفتار اتصال با صحت کافی استفاده نمود. پس از آن پارامترهایی چون ضخامت ورقهای انتهایی، قطر پیچ و نیروی پیش تنیدگی پیچ را برای اتصال پیچ کور ورق های انتهایی توسعه یافته و هم-تراز تیر فولادی به ستون توخالی تحت بارگذاری چرخه ای با نرم افزار ABAQUS مورد ارزیابی قرار داده و منحنی هیسترزیس لنگر- دوران هر کدام از آن ها بدست آمدند. نتایج نشان دادند که ضخامت ورق انتهایی، قطر پیچ و نیروی پیش تنیدگی پیچ در رفتار اتصال تأثیر گذار هستند.https://www.jsce.ir/article_82836_fcdf56368a3dd4ecab2a80bdd42f9e3f.pdfانجمن مهندسی سازه ایرانمهندسی سازه و ساخت2476-39778120210321Seismic Evaluation of Frame with Belt Truss by Incremental Modified Pushover Analysis (IMPA)ارزیابی لرزه ای قاب های خمشی محیطی مجهز به کمربند خرپایی با تحلیل نوین غیرخطی اصلاح شده فزاینده (IMPA)23418292210.22065/jsce.2019.117924.1453FAحامد غلامی حیدرآبادیدانشجوی کارشناسی ارشد، گروه عمران، دانشکده فنی مهندسی، دانشگاه خوارزمی، تهران، ایرانجعفر کیوانی قمصریدانشیار، دانشکده فنی و مهندسی، دانشگاه خوارزمی، تهران،0000-0002-8689-1996سید حسین حسینی لواسانیاستادیار، گروه عمران ، دانشکده فنی مهندسی، دانشگاه خوارزمی، تهران، ایران0000-0002-9524-9399Journal Article20180203Nowadays, nonlinear static and dynamic analyses methods are rapidly expanding to evaluate the seismic performance of structures. Nonlinear dynamic analyses methods require a large amount of computations and are relatively time consuming. This fact has led to the emergence of novel methods based on the concepts of nonlinear static and dynamic analyses. One of the most widely used structures in tall buildings is a combination of the two popular building structures: Bundled tube frame and belt truss. This structural form is effective in reducing the structure responses to lateral loadings. In this paper, two 20-story Steel buildings with different arrangement of resistant rigid belt truss in the 19th and 20th stories have been evaluated under 7 pairs of far and near-field scaled ground motion. Incremental dynamic (IDA), Incremental modified Pushover (IMPA), modal pushover (MPA), and dynamic time history analyses have been conducted to evaluate the seismic response of the structures. The accuracy of the IMPA method has been compared to that of the Incremental Dynamic Analysis (IDA), and a comparison has been also made between nonlinear behavior of the studied models, with and without the belt truss. Results indicate the significant difference in the story drift in the three aforementioned structural configurations under high-amplitude speed pulses. Structures stiffened with belt truss at higher levels of PGA have collapsed and the seismic capacity of the frame has been increased in the upper floors. Maximum relative displacement has been occurred in the inelastic response area near the middle stories.امروزه به منظور ارزیابی لرزه ای سازه ها روش های تحلیل استاتیکی و دینامیکی غیر خطی به سرعت درحال گسترش است. روش های تحلیل دینامیکی غیر خطی به حجم زیاد محاسبات نیازمند بوده و بیشتر زمان بر هستند. این موضوع باعث پدید آمدن روش های نوین براساس مفاهیم مربوط به تحلیل های استاتیکی و دینامیکی غیر خطی شده است. یکی از فرم های سازه ای پرکاربرد در سازه های بلند استفاده از ترکیب دو قاب خمشی محیطی دسته شده و کمربند سخت کننده خرپایی می باشد. این فرم سازه ای در کاهش پاسخ سازه دربرابر بارهای جانبی تاثیر دارد. در این پژوهش به ارزیابی مدل های مطالعاتی سازه 20 طبقه با قاب خمشی محیطی دسته شده با دو آرایش اسکلت مقاوم کمربند خرپایی در طبقات 19 و 20 سازه با استفاده از 7 رکورد مقیاس شده حوزه دور و نزدیک گسل، دارای پالس های بزرگ سرعت، تحلیل دینامیکی غیر خطی فزاینده (IDA) و تحلیل استاتیکی غیر خطی اصلاح شده فزاینده (IMPA) و تحلیل استاتیکی غیر خطی مودال (MPA) و تحلیل دینامیکی تاریخچه زمانی انجام گرفته است. دقت روش IMPA نسبت به روش تحلیل دینامیکی فزاینده (IDA) مقایسه گردیده و همچنین مقایسه ای بین رفتار جانبی غیر خطی مدل ها، با مهار کمربند خرپایی و بدون مهار کمربند خرپایی با استفاده از تحلیل استاتیکی غیر خطی بار افزون انجام گرفته است؛ نتایج حاصله نشان دهنده تفاوت معنا دار پارامتر دریفت بین سه پیکربندی یاد شده تحت پالس های پر دامنه سرعت می باشد. سازه های مجهز به مهار کمربند خرپایی در تراز بالاتری از PGA دچار گسیختگی شده و ظرفیت شدت لرزه ای قاب در طبقات بالایی افزایش داده است. تغییر مکان نسبی بیشینه در ناحیه پاسخ غیر الاستیک در حوالی طبقات میانی رخ داده است.https://www.jsce.ir/article_82922_873b1b25bd46469df4cb3669048ca93b.pdfانجمن مهندسی سازه ایرانمهندسی سازه و ساخت2476-39778120210321Analytical study of the effect of LRB isolators positioning at the base and inter-story levels on seismic response of RC buildingsمطالعه عددی تأثیر قرارگیری جداسازهای لاستیکی با هسته سربی در حالتهای جداسازی شده پایه و میان طبقه ای بر رفتار سازههای بتن آرمه42618294610.22065/jsce.2019.155463.1703FAابراهیم زمانی بیدختیعضو هیات علمی، دانشگاه صنعتی شاهرود،دانشکده عمران، شاهرود، ایرانامیرمحمد تقویدانشجوی کارشناسی ارشد عمران، دانشکده مهندسی عمران، دانشگاه صنعتی شاهرود، شاهرود، ایران0000-0003-4922-0859حامد کوهستانیاندانشجوی کارشناسی ارشد عمران، دانشکده مهندسی عمران، دانشگاه صنعتی شاهرود، شاهرود، ایرانJournal Article20181108In this study, the effect of isolators positioning at three Levels and different arrangements on seismic response of RC buildings are investigated. For this purpose 18 RC building of 4, 8 and 12 story with and without lead rubber bearing (LRB) isolators were selected. The LRB isolators positioned at three Levels and five different arrangements were modeled in Opensees software. The near field and far fault earthquakes were added to the frames and incremental dynamic analysis was performed. The fragility curves base on inter-story drift ratio as well as the IDA curves base on maximum inter-story drift ratio, maximum base shear, maximum roof displacement and acceleration versus peak ground accelerations (PGA) were plotted and compared. The results showed that among the isolated structures, the isolator positioning at the level of below the first floor (type 1 and type 2) had the best performance in reducing responses. The positioning type 1 (MSI-1) resulted the best decreasing in inter-story drift ratio and base shear. In addition, this type of isolator had the best increasing the PGA according to median fragility between the different types of the positioning levels. The recommended type of isolator had the best performance, especially in high rise buildings in severe damage levels.در این مقاله تأثیر قرارگیری جداسازهای لاستیکی با هسته سربی در حالتها و ترازهای ارتفاعی مختلف بر رفتار سازههای بتن آرمه تحت اثر زلزلههای حوزه نزدیک و دور مورد بررسی قرار گرفت. ازاینرو، برای جداسازهای لاستیکی با هسته سربی در سه نمونه سازههای بتنی ۴، ۸ و ۱۲ طبقه سه تراز ارتفاعی با پنج آرایش مختلف در نحوه قرارگیری آنها در نظر گرفته شد. این سازهها به همراه سازههای پایه ثابت مشابه در نرمافزار Opensees مدل گردیده و تحت اثر زلزله های دور و نزدیک، تحلیل دینامیکی افزایشی بر روی آنها انجام گرفت. درنهایت، برای این سازهها، منحنیهای تحلیل دینامیکی افزایشی بر اساس شاخصهای خسارت ماکزیمم دریفت طبقات، ماکزیمم برش پایه، ماکزیمم جابجایی و شتاب بام در برابر شاخص شدت بیشینه شتاب زمین ترسیم شد. همچنین با رسم منحنیهای شکنندگی بر اساس ماکزیمم دریفت طبقات در برابر بیشینه شتاب زمین تفسیرهای قابل قبولی ارائه گردید و احتمال خرابی در هر یک از سطوح آسیب به کمک رسم میانه منحنیهای شکنندگی مورد بررسی گرفت. نتایج بهدست آمده نشان داد که قرارگیری جداسازها در حالت های میان طبقه ای 1 و 2 دریفت طبقات و برش پایه را به کمتر از نصف کاهش می دهند. در این میان قرارگیری جداساز در سطح زیرین طبقه اول (حالت1) بهترین عملکرد رفتاری در کاهش دریفت و برش پایه و افزایش شتاب متناظر با میانه شکنندگی در بین سازههای جداسازی شده در حالات مختلف بخصوص در سازه های بلند با سطوح خسارت بالا داراست.https://www.jsce.ir/article_82946_74d5e0c22d14ca1caf0a42b26f7c17ed.pdfانجمن مهندسی سازه ایرانمهندسی سازه و ساخت2476-39778120210321Development of efficiency index for steel moment frames with Self-Centering Connectionsتدوین شاخص کارایی قابهای خمشی فولادی دارای اتصالات مرکز گرا628110697410.22065/jsce.2020.223402.2106FAمحمد باوندیدانشجوی دکتری مهندسی سازه، گروه مهندسی عمران، واحد علوم و تحقیقات، دانشگاه آزاد اسلامی، تهران، ایران0000-0001-5555-3313عبدالرضا سروقد مقدمدانشیار، پژوهشگاه بین المللی زلزله شناسی و مهندسی زلزله، تهران، ایران0000-0002-3831-8757محمد رضا منصوریاستادیار، گروه مهندسی عمران، واحد علوم و تحقیقات، دانشگاه آزاد اسلامی ، تهران، ایران0000-0003-3895-6326آرمین عظیمی نژاداستادیار، گروه مهندسی عمران، واحد علوم و تحقیقات، دانشگاه آزاد اسلامی ، تهران، ایران0000-0001-9973-1361Journal Article20200313Traditional earthquake-resistant systems are dependent on the inelastic response of the building members. These systems experience significant residual displacements after major earthquakes due to seismic energy distribution all over the building and make their repair uneconomical. Self-Centering systems in steel frame buildings omit residual displacements and concentrate building damage on Self-Centering connection and reduce the cost of repair. Due to the dispersion of the response of Self-Centering systems against different earthquakes, it is necessary to determine an index to control sensitivity of these systems against various records. In this paper, developing an efficiency index of steel moment frame systems with Self-Centering connections using the dispersion index's methodology is discussed. After performing the time history dynamic analyses of two steel buildings with 3 and 9 floors, six types of self-centering connections for each frame with seven dispersion indices were evaluated. Decreased dispersion of responses indicate that the system is more efficient. Among these, under the optimization of indices, it is tried to select an index with a better performance which resulted to CV index (coefficient of variation). Finally, the structure with the least dispersion of responses is selected from the viewpoint of efficiency. The selected model of this research for 3 and 9 story buildings is model M5 which is the fifth model of Moradi models.*سیستم های سنتی مقاوم در برابر نیروهای زلزله، وابسته به پاسخ های غیر الاستیک دراعضای ساختمانی می باشند. این سیستمها در سراسر ساختمان برای توزیع انرژی لرزهای ممکن است جابجاییهای پسماند قابل توجهی بعد از زلزله های بزرگ را تجربه کنند و باعث غیر اقتصادی شدن تعمیر در آنها شوند. سیستم های مرکز گرا در ساختمان های قاب فولادی تغییرمکان ماندگار را حذف خواهند کرد و خرابی ساختمان را دراتصالات مرکز گرا متمرکز میکنند و هزینه تعمیر را کاهش میدهند. با توجه به پراکندگی پاسخ سیستم های مرکز گرا در برابر زلزله های مختلف، تعیین شاخصی برای کنترل حساسیت این سیستم ها در برابر زلزله های مختلف الزامی است. دراین مقاله به تدوین شاخص کارایی سیستم های قاب خمشی فولادی دارای اتصالات مرکز گرا با استفاده از متدولوژی شاخصهای پراکندگی پرداخته شده است. بعد از انجام تحلیل دینامیکی تاریخچه زمانی دو ساختمان 3 و 9 طبقه فولادی، شش نوع اتصال مرکز گرا برای هر قاب با هفت شاخص پراکندگی تحت ارزیابی قرار گرفته اند. کاهش میزان پراکندگی پاسخ ها نشان دهنده کاراتر بودن سیستم مورد بررسی می باشد. که از این بین تحت بهینهیابی شاخص ها، سعی درانتخاب شاخصی با عملکرد بهتر شده است. که این شاخص ضریب تغییرات(CV) می باشد. در انتها سازه ای از دیدگاه کارایی مورد قبول است که در ارزیابی مورد نظر به عنوان مدل منتخب با کمترین حساسیت نسبت به پراکندگی در پاسخ سازه معرفی شود. مدل منتخب در این تحقیق برای ساختمان های 3 و 9 طبقه مدل M5 می باشند که مدل پنجم از مدل های مرادی است.*https://www.jsce.ir/article_106974_f5d100934d1212b3715ccf0ee6ed3f14.pdfانجمن مهندسی سازه ایرانمهندسی سازه و ساخت2476-39778120210321Evaluation of silica-fume effect on the mechanical properties of concrete with fine recycled aggregatesارزیابی تاثیر میکروسیلیس بر خواص مکانیکی بتن های با سنگدانه های ریز بازیافتی بتنی82968323210.22065/jsce.2019.155730.1705FAسیدفتح اله ساجدیدانشیار، گروه مهندسی عمران، واحد اهواز، دانشگاه آزاد اسلامی، اهواز، ایران0000-0003-3933-2793رضا افشاردانشجوی دکتری، گروه عمران، واحد اهواز، دانشگاه آزاد اسلامی، اهواز، ایرانJournal Article20181110Today, it is quite clear that the speed of development of infrastructure in developing countries has led to much damage to the environment. Concrete is one of the products that plays an important role in the use of non-renewable resources. Today, the vision of sustainable development in the manufacturing industry is growing and increasing, and concrete is at the forefront of this as one of the most widely used construction products. The present study investigates the effect of the use of silica-fume (SF) pozzolan powder on the mechanical properties of recycled concrete made from fine recycled aggregates. Recycled concretes consists of different levels of replacement of fine recycled concrete with natural fines. In order to improve the quality of recycled concrete, Pozzolan was introduced at various levels with cement. To determine and compare the mechanical properties of concrete, 12 mixing designs were made and compressive strength tests at 7, 28 and 91 days, tensile strength, and ultrasound velocity at 28 days of age were performed. The results showed that, generally speaking, in the 28-day period, the use of SF can cause 25% recycled concretes to achieve a desirable 40 MPa strength. The use of 10% SF replacement rate, especially in concrete containing 25% recycled aggregates, made the mechanical properties of recyclable concretes significantly closer to conventional concrete.امروزه کاملا روشن گردیده که سرعت توسعه زیرساختهای عمرانی در کشورهای در حال توسعه منجر به وارد آمدن آسیبهای فراوانی به محیط زیست شده است. بتن یکی از محصولاتی است که نقش زیادی در مصرف منابع تجدیدناپذیر دارد. امروزه نگاه مبتنی بر توسعه پایدار در صنعت ساخت در حال رشد و فزونی است و بتن به عنوان یکی از پرمصرفترین محصولات ساختمانی در صدر این نگاه قرار گرفته است. تحقیق حاضر به بررسی تاثیر استفاده از پودر پوزولان میکروسیلیس بر خواص مکانیکی بتنهای بازیافتی ساخته شده از سنگدانههای ریز بازیافتی بتنی پرداخته است. بتنهای بازیافتی، متشکل از سطوح مختلف جایگزینی ریزدانههای بازیافتی بتنی همراه با ریزدانههای طبیعی هستند. جهت بهبود کیفیت بتنهای بازیافتی، پوزولان معرفی شده در سطوح مختلفی با سیمان جایگزین شد. جهت تعیین و مقایسه خواص مکانیکی بتنها، 12 طرح اختلاط ساخته شده و آزمایشهای مقاومت فشاری در سنین 7، 28 و 91 روزه، مقاومت کششی دونیم شدن و سرعت امواج فراصوت در سن 28 روزه انجام شدند. نتایج نشان دادند که به طور کلی در بازه 28 روزه، استفاده از میکروسیلیس میتواند باعث شود تا بتنهای %25 بازیافتی به مقاومت مطلوب 40 مگاپاسکالی دست یابند. استفاده از سطح جایگزینی %10 میکروسیلیس، به ویژه در بتنهای حاوی %25 مصالح بازیافتی، باعث گردید تا خواص مکانیکی بتنهای بازیافتی به میزان چشمگیری به بتنهای معمولی نزدیک گردند.https://www.jsce.ir/article_83232_a46ab508474c227308fe2653aab25e85.pdfانجمن مهندسی سازه ایرانمهندسی سازه و ساخت2476-39778120210321Proposed new methods for modifying the mechanical characteristics of the artificial stoneپیشنهاد روش هایی برای اصلاح مشخصات مکانیکی سنگهای مصنوعی گرانیتی971108425310.22065/jsce.2019.151172.1676FAاحمد علی نژاددانشجوی کارشناسی ارشد رشته مهندسی ساختمانهای هوشمند، دانشکده فناوری های برتر، دانشگاه تربیت مدرس، تهران، ایرانصادق دردائیاستادیار دانشکده فناوری های برتر، دانشگاه تربیت مدرس، تهران، ایرانحامد باقریاستادیار دانشکده فناوری های برتر، دانشگاه تربیت مدرس، تهران، ایرانJournal Article20181005In this paper, factors affecting the mechanical properties of polymeric granite artificial stone have been investigated. Epoxy resin and three types of additives called Poly ether ether ketone, Silicon rubber, and Nanoclay have been used to make the artificial stone. Unlike previous research on resin alone, this study has been conducted on artificial stone and samples made using these materials. These samples are compared with the control sample and the sample with optimal mechanical characteristics. The method of making artificial stone is that crushed stone blend with resin, and is molded into molds that are defined according to the American Association of Materials and Testing. Samples were made with two percentages of 7.5 and 15 percent to determine the optimum amount of additive. After curing, the sample is subjected to testing. The results obtained from these experiments for artificial stone show that the addition of polyether ether ketone to epoxy resin compressive strength by more than 30%. 7.5wt% of Nanoclay increases more than 6% in compressive strength in epoxy resin. Therefore, the amount of 7.5% by weight of the additive has been selected as the optimum percentage and only this percent is considered in the manufacture of flexural and tensile strength samples. Adding Silicon rubber to the epoxy resin, increases the flexural strength by 7%. Contrary to expectation, Nanoclay reduces flexural strength significantly. By examining the results of the tensile test, it was determined that the addition of silicon to the epoxy resin increased the resistance to 46% . It is concluded that the addition of silicon rubber has been effective in increasing the compressive strength and in increasing the flexural and tensile strength and adding polyether ether ketone.سنگ مصنوعی گرانیتی محصولی است کامپوزیتی که از ترکیب سنگدانه گرانیت، رزین و مواد افزودنی تولید می شود. در این مقاله، روش هایی برای اصلاح مشخصات مکانیکی سنگ مصنوعی گرانیتی معرفی شده است. رزین استفاده شده در ساخت سنگ مصنوعی گرانیتی شامل رزین اپوکسی از نوع دیگلیسیدیل اتر بیس فنول نوع آ با نام تجاریEPONATE 557 و سختکننده آن با نام EPONATE 567 می باشد. در این پژوهش برای اصلاح مقاومت مکانیکی سنگهای مصنوعی گرانیتی، روشهای مناسب، مانند استفاده از سه ماده افزودنی "نانوکلی"، "پلی اتر اترکتون" و "سیلیکون رابر" به عنوان مواد افزودنی با درصد وزنی 5/7% و 15% نسبت به مجموعه رزین انتخاب و درصد وزنی بهینه برای رسیدن به حداکثر مقاومت، بررسی و پیشنهاد گردیدهاست. نتایج مربوط به آزمایش مقاومت فشاری نشاندهنده بهبود مقاومت در نمونههای با ماده افزودنی پلی اتر اترکتون و نانوکلی میباشد، درحالیکه افزودن سیلیکون رابر باعث افت قابل توجه مقاومت فشاری میشود. نتایج مربوط به آزمایش مقاومت خمشی نشان دهنده بهبود مقاومت در نمونههای ساخته شده با ماده افزودنی سیلیکون رابر میباشد. همچنین نتایج مربوط به آزمایش مقاومت کششی نشان از بهبود خواص کششی در نمونههای ساخته شده با سیلیکون رابر میدهد. نتایج نشان میدهد که افزودن 15درصد وزنی از هر سه ماده افزودنی در نمونهها، باعث افت مقاومت سنگ نسبت به نمونههای 5/7 درصد وزنی میگردد. بر اساس نتایج برای اصلاح مقاومت فشاری سنگهای مصنوعی گرانیتی استفاده از مواد افزودنی "پلی اتر اترکتون" با درصد وزنی 5/7 نسبت به مجموعه رزین و برای اصلاح مقاومت خمشی و کششی سنگ مصنوعی استفاده از ماده افزودنی سیلیکون رابر با درصد وزنی 5/7 درصد وزنی نسبت به مجموعه رزین پیشنهاد میگردد.https://www.jsce.ir/article_84253_635e8ceb11d21a7a80c6363ea9fccfad.pdfانجمن مهندسی سازه ایرانمهندسی سازه و ساخت2476-39778120210321Management of Optimum Design and Construction on Landfillsمدیریت طراحی و ساخت بهینه بر روی مدفن های ضایعات ساختمانی و اجرایی1111308425410.22065/jsce.2019.159031.1722FAمجید احمدپورعضو هیئت علمی دانشکده معماری دانشگاه مازندران، بابلسر، ایرانJournal Article20181128Assessment and investigation of soil and bedrock properties is of an essence for construction of residential, commercial as well as industrial complexes. In order for the foundation system of such projects to be opted, it is necessary to assess the geotechnical characteristics of the site. In many projects where the site is located on problematic soils or non-engineered fills, if the accumulation of the soil is done with no specific consideration of controlling the fill thickness and compaction, the soil will experience some major problems regarding volumetric changes, bearing deficiencies, and internal instability. Therefore, it is crucial in such fills to employ some soil improvement and preservation measures in accordance with their materials, time and circumstance of the fill formation. In construction procedure of a complex near Tehran, due to non-engineered accumulation of debris and inappropriate compaction, it was recognized that the project was prone to unallowable differential settlement and instability, and for this reason, it was required to improve the subsoil properties by means of ground improvement techniques. Moreover, owing to the significant depth of problematic soils, the shallow improvement approaches would not suffice, and consequently, using semi-deep or deep improvement techniques were mandatory. In this paper, the geological characteristics of the site in line with assessment of the soil geotechnical properties after improvement were analyses in order to select the more appropriate improvement methods. Among different alternatives, the combination of earth works, shallow compaction, jet grouting and employing micropiles was shown to be the more optimum option from economical, technical, and feasibility perspectives, and therefore, was employed in the project.برای احداث شهرکها، مجموعه های ساختمانی و اماکن تجاری و صنعتی بررسی و مطالعات مصالح خاکی و سنگ بستر تحت عنوان مطالعات ژئوتکنیک از اهمیت ویژهای برخوردارند. برای انتخاب نوع و چگونگی پیها و زیرسازه این اماکن خصوصیات زمینشناسی مهندسی ساختگاه باید مورد بررسی قرار گیرد. در بسیاری از فعالیتهای عمرانی، ساختگاه پروژه در اعماق سطحی متشکل از خاکهای مسئلهدار دستی یا خاکریزهای غیرمهندسی میباشد. اگر انباشتن خاکهای ذکر شده بهصورت انبوهی و بدون درنظر گرفتن تمهیدات ویژه مربوط به ضخامت خاکریزی و متراکمسازی صورت گیرد، پس از بارگذاری ناشی از ساخت و ساز، عوارضی از قبیل تغییرات حجمی، ضعف باربری و ناپایداری داخلی را بهدنبال خواهد داشت. در مجموع در انواع خاکریزهای غیرمهندسی متناسب با نوع ماده متشکله آنها، زمان و چگونگی جاگذاری، گستره آنها در پلان و پروفیل و چگونگی فعالیتهای عمرانی برروی آنها اقدامات ویژه بهسازی و محافظت ضروری میباشد. برای یک مجموعه ساختمانی در اطراف تهران بهدلیل انباشت غیراصولی نخالهها و در نتیجه تراکم نامناسب و طبیعت متخلخل، وقوع نشستهای غیرعادی در اثر اعمال بارهای سازهای بسیار محتمل بود، بههمین دلیل اقدامات ویژه بهسازی و محافظتی ضروری میشود. همچنین با توجه به عمق قابل توجه لایههای خاکدستی، بهسازی سطحی به تنهایی کافی نبوده و میبایست روشهای بهسازی نیمه عمیق و یا عمیق جهت کنترل شرایط موجود به کار گرفته میشد. در این مقاله رابطه خصوصیات زمینشناسی مهندسی ساختگاه پروژه و ارزیابی پارامترهای ژئوتکنیکی خاکهای دستی بهسازی شده در انتخاب نوع و روشهای بهسازی مورد بررسی قرار گرفت. روشهای خاکبرداری، متراکمسازی سطحی، تزریق انبوهی بستر و ریزشمع به عنوان مناسب ترین گزینه از منظر اقتصادی، فنی و اجرایی انتخاب و مورد آزمایش قرار گرفتند. در مجموع با حصول اهداف بهسازی و مقاومسازی شالوده و تأمین اهداف ژئوتکنیکی، اقدامات معمول پی سازی سطحی برای زیرسازه تحقق یافت.https://www.jsce.ir/article_84254_da8e339d95ac899cc3814b10f75d29e4.pdfانجمن مهندسی سازه ایرانمهندسی سازه و ساخت2476-39778120210321Experimental study of the effect of dynamic loading on rectangular armed panels made of self-compacting composite fiber and lattice sheetsبررسی آزمایشگاهی تاثیر بارگذاری دینامیکی بر پنل های مسلح مستطیلی ساخته شده با کامپوزیت سیمانی خود تراکم الیافی و ورق های مشبک1311518425510.22065/jsce.2019.161505.1741FAاحمد دالونداستادیار، گروه عمران، دانشگاه لرستان، خرم آباد، ایرانحسین حاتمیاستادیار، گروه عمران، دانشگاه لرستان، خرم آباد، ایران0000-0002-6235-6569آرزو صیدی چگنیدانشجوی کارشناسی ارشد، دانشگاه لرستان، خرم آّباد، ایرانJournal Article20181216The nature of dynamic loading is different due to the high force in a few milliseconds with static loading. The amount of energy absorption and energy loss in composite materials is a suitable measurement to evaluate the performance against impact loads. On the other hand, the use of self-compacting composites due to its unique properties has attracted the attention of researchers. High compressive and tensile strength, high flexural strength, has attracted more attention from researchers to this kind of cement composites. In this research, in the form of a comprehensive laboratory work, using four basement mixing designs, 64 rectangular composite panels were constructed in two groups of 100*100 mm with four thicknesses of 30, 45, 60 and 75 mm and tested under dynamic loading. Tensile and flexural strength tests were made on all four mixing designs. Steel fibers with percentages of 0, 0.25, 0.5 and 0.75 with length of 25 mm were used for the construction of cement composites. The drop hammer test machine with weighs 180 kg and the power of 7500 J is used. According to laboratory results, the combined use of steel and fiber reinforced steel sheets increased the energy absorption considerably. Also, the initial peak force increased and the deformation length decreased.ماهیت بارگذاری های ضربه ای و دینامیکی به دلیل اعمال نیروی زیاد در چند میلی ثانیه با بارگذاری استاتیکی متفاوت می باشد. میزان جذب و استهلاک انرژی در مواد کامپوزیتی، معیاری مناسب به منظور بررسی عملکرد آنها در برابر بارهای ضربه ای می باشد. جاذب های انرژی به طور وسیعی در صنعت مورد استفاده قرار می گیرد. از طرفی استفاده از کامپوزیت های توانمند خود تراکم به دلیل ویژگی های منحصر به فرد آن، مورد توجه محققین قرار گرفته است. مقاومت فشاری و کششی بالا، مقاومت خمشی بالا موجب توجه بیش از پیش محققین به این نوع از کامپوزیت های سیمانی شده است. در این تحقیق بصورت یک کار جامع آزمایشگاهی با استفاده از 4 طرح اختلاط پایه، 64 پنل کامپوزیتی مستطیلی در دو گروه به ابعاد 100 در 100 میلیمتر با چهار ضخامت 30، 45، 60 و 75 میلیمتر ساخته و تحت بار ضربه ای دینامیکی تست شده اند. بر روی هر چهار طرح اختلاط ساخته شده، آزمایش های مقاومت فشاری، کششی و خمشی انجام گردید. از الیاف فولادی با درصد های 0، 25/0، 5/0 و 75/0 با طول 25 میلیمتر به منظور ساخت کامپوزیت های سیمانی استفاده شد. دستگاه آزمایش ضربه از چکشی به وزن 180 کیلوگرم و توان 7500 ژول در این تحقیق استفاده شده است. نمونه ها با ارتفاع سقوط 600 میلیمتر، تحت بار گذاری دینامیکی قرار گرفته اند. مطابق با نتایج آزمایشگاهی مشاهده گردید که استفاده ترکیبی از الیاف و ورق های مشبک فولادی به صورت ترکیبی، موجب افزایش میزان جذب انرژی به طور قابل ملاحظه ای شد. همچنین نیروی پیک اولیه نیز افزایش یافت و همچنین طول لهیدگی و تغییر شکل نمونه کاهش یافت.https://www.jsce.ir/article_84255_523519d2ddf9ccdcf3ad12e530fc560f.pdfانجمن مهندسی سازه ایرانمهندسی سازه و ساخت2476-39778120210321Investigation of the Effect of TADAS Yielding plate damper in Low and Mid Rise of Steel Structures under the Near and far Fault Zoneتاثیر میراگرTADAS در سازه های فولادی تحت زلزله حوزه دور و نزدیک گسل1521728510010.22065/jsce.2019.119969.1475FAسیروس غلامپوراستادیار، گروه مهندسی عمران، واحد قائمشهر، دانشگاه آزاد اسلامی، قائمشهر، ایرانعلی ناصریدانشجوی دکتری عمران سازه، دانشگاه صنعتی نوشیروانی ، بابل ، ایران0000-0003-4537-472Xغزاله متولیکارشناسی ارشد عمران،سازه،مؤسسه آموزش عالی،پردیسان،فریدونکنار،ایرانJournal Article20180219زلزله یکی از آشناترین پدیده های طبیعی است که به دلیل عدم امکان پیش بینی زمان وقوع و پیشگیری از زمین لرزه به دنبال خود خسارات جانی و مالی بسیاری را به همراه دارد و ایران با ساختار ویژه لرزهزمین ساخت، وجود گسلهای فعال و لرزهخیزی زیاد در زمره مناطق با خطر بالای زلزله در جهان قرار دارد. یکی از ابزارهای کنترل رفتار سازه استفاده از میراکننده ها است. میراگرهای تسلیمی برای مستهلک کردن انرژی از سرعت و جابجایی نسبی طبقات قاب در سازه ها استفاده می کنند. در این مقاله برای درک بهتر از تاثیر تعداد طبقات و تعداد دهانه ها در رفتار لرزه ای میراگرها، سازه ها در 16 حالت شامل، چهار مدل سازهای با تعداد طبقات و دهانه های متفاوت (4 طبقه تک دهانه، 4 طبقه سه دهانه، 2 طبقه تک دهانه، 2 طبقه سه دهانه) در دو حالت با میراگر TADAS و بدون میراگر بررسی شدند. سازه ها در نرم افزار sap به صورت کاملاً غیر خطی و تحت دو مجموعه 7تایی رکورد دور از گسل و نزدیک گسل تحلیل دینامیکی غیرخطی گردیدند. نتایج نشان می دهد که وجود این نوع میراگر پاسخ های سازه شامل دریفت و برش در حالت دور از گسل به ترتیب به میزان 85/20 و12/21درصد و در حالت نزدیک گسل به میزان 30/23و 84/26درصد کاهش می دهد.The earthquake is one of the natural phenomena, this is due to the impossibility to predict the time of the occurrence and impossibility prevention of earthquakes and then followed many physical's and financial Damage and Iran with the particular structure of the quake there, active and Seism tectonics in granite is among the areas with high risk of earthquakes in the world. One of the tools to control the behavior of the structures is the use of the Dampers .Structural control means that the characteristics of the dynamic behavior of structures to be set up in a way that the structural response under the effect of external irritation about not allowed outside .TADAS Yielding plate damper for loses of energy from controlled the speed and relative displacement of frame structures using classes ,Be aware of the performance and impact of the damper efficiency, engineers use them to help reduce the damage caused by the earthquake. Structural models consist of a four-story structure model, one span and three spans, and a two-story, one-and three-span structures, which were completely non-linear in sap software. And then same structure check with TADAS Damper on far from and near fault. The results show that the presence of this type of damper, the structural responses including drift and shear in the far-off faults are 20.85 and 21.12 respectively, and in the near-fault state, decreases by 23.30 and 26.84%, respectivelyhttps://www.jsce.ir/article_85100_dc69308470c86cd1254e77203f30aa95.pdfانجمن مهندسی سازه ایرانمهندسی سازه و ساخت2476-39778120210321An analytical study on the effect of beams' impact on the stories of structure with attitude towards progressive collapseبررسی تحلیلی اثرات ضربه تیرها در طبقات سازه با نگرشی بر تخریب پیشرونده1731928510110.22065/jsce.2019.159652.1727FAقاسم گرجی بندپیدانشجوی مقطع دکتری مهندسی عمران- سازه، دانشگاه صنعتی نوشیروانی بابل، بابل، ایرانغلامرضا عبداله زاده درزیدانشیار گروه مهندسی عمران، دانشکده عمران, دانشگاه صنعتی نوشیروانی بابل، بابل، ایرانعلی رحمانی فیروزجائیاستادیار گروه مهندسی عمران، دانشکده عمران, دانشگاه صنعتی نوشیروانی بابل، بابل، ایران0000-0001-6874-7635Journal Article20181203By reviewing previous studies in the field of roof’s collapse, an efficient analytical method is required to simulate the impact mechanism and failure procedure. Hence, the purpose of present study is mainly to analyze the beams' impact. Consequently, upper and lower beams are considered to survey the collision effects of upper beam’s equivalent concentrated mass to the lower beam’s midspan in a way that an initial impact caused by mass is taken into account. At first, the maximum bending moment at the midspan is calculated by assuming linear behavior and employing the relations which involves the kinetic energy of concentrated mass and potential energy of the lower beam. Then, studying a conventional steel frame demonstrates that the bending moment is about eight times greater than the bending moment capacity of lower beam, therefore it would lead to formation of a plastic hinge at the midspan. In continue, the mentioned relations are solved by using the equations of motion including inertial effect. The results are used to calculate velocity in different sections of lower beam. Subsequently, the equilibrium equation is employed in the middle of lower beam and a virtual hinge at an arbitrary section which is tending in a wave form to supports is considered. Due to mentioned assumptions by investigating hinge formation behavior, the time of hinge tendency to the supports is calculated. Additionally, displacement values along the lower beam are obtained. Finally, the diagrams and tables are represented by using the obtained equations and compared with the lower beam's displacement capacity. The results demonstrate that the lower beams will collapse due to the collision of concentrated mass of upper beam and progressive collapse occurs in lower stories. Finally, for more accuracy of present study, the effect of secondary impact of upper beam on the lower beam is considered.با مرور مطالعات پیشین در حوزه فروریزش سقف سازه، جای خالی یک روش تحلیلی کارآمد که بتواند مکانیزم ضربه و نحوه گسترش خرابی در تیرها را به نحو مطلوبی مدلسازی نماید احساس میشود. لذا در این مطالعه به بررسی تحلیلی اثرات ضربه تیرها پرداخته شده است. بدین منظور در ابتدا اثرات برخورد جرم معادل متمرکز ناشی از تیر فوقانی بر روی تیر تحتانی مورد بررسی قرار می-گیرد و با فرض رفتار خطی و با استفاده از روابط انرژی جنبشی جرم و انرژی پتانسیل تیر تحتانی، مقدار لنگر وارده ناشی از ضربه در محل ماکزیمم لنگر که وسط دهانه میباشد محاسبه گردید و سپس با در نظر گرفتن یک سازه فولادی متعارف، نتایج محاسبات نشان میدهد که لنگر وارده از لنگر حد تسلیم تیر تحتانی بیش از هشت برابر بزرگتر میباشد و لذا در وسط دهانه لولای پلاستیک بوجود خواهد آمد. در ادامه با استفاده از معادله حرکت، تابع سرعت در نقاط مختلف تیر تحتانی محاسبه گردیده است و با استفاده از رابطه تعادل لنگر در محل وسط دهانه و یک نقطه دلخواه که آن نقطه در واقع محل لولای فرضی است که به صورت موج در حال رسیدن به تکیهگاه ها میباشد، زمان رسیدن لولا به تکیهگاهها بدست آمده است و همچنین تابع تغییرمکان در نقاط مختلف تیر تحتانی محاسبه شده است. سپس نمودارها و جداول مربوطه ترسیم گردیده و این نمودارها با نمودار ظرفیت نهایی تغییرمکان تیر تحتانی مقایسه گردید که نتایج نشان میدهد تیر تحتانی تحت اثر ضربه ناشی از جرم معادل تیر فوقانی دچار تخریب خواهد شد و گسترش خرابی به تیرهای زیرین رخ خواهد داد. در پایان جهت افزایش دقت مدلسازی ضربه تیر فوقانی به تحتانی، اثرات ضربه ثانویه طرفین تیر فوقانی مدلسازی و محاسبه گردید. نتایج نشان میدهد ضربه ثانویه نسبت به ضربه اولیه جرم معادل تیر فوقانی اثر ناچیزی در پاسخهای تیر تحتانی دارد.https://www.jsce.ir/article_85101_f3068b6775614110ca9fd4127fba0984.pdfانجمن مهندسی سازه ایرانمهندسی سازه و ساخت2476-39778120210321Comparison of nonlinear static analysis of Iranian standard 2800 with ASCE/SEI 41-13 in intermediate MRF RC buildingsمقایسه روش تحلیل استاتیکی غیرخطی استاندارد 2800 ایران با آییننامه ASCE/SEI 41-13 آمریکا در ساختمانهای بتنآرمه با سیستم قاب خمشی متوسط1932198570910.22065/jsce.2019.148234.1679FAبهادر حبیبی پورزارعگروه عمران، دانشکده فنی، دانشگاه شهید مدنی آذربایجان، تبریز، ایرانعبدالحسین فلاحیعضو هیات علمی دانشکده مهندسی عمران دانشگاه شهید مدنی آذربایجانارژنگ صادقیگروه عمران، دانشکده فنی، دانشگاه شهید مدنی آذربایجان، تبریز، ایرانJournal Article20181007One of the simplified methods, which is progressing and completing every day, is a nonlinear static analysis that can directly evaluate the performance of a structure in any limit state and provide information about the nonlinear behavior of the structure, and it also does not have the complexity of nonlinear dynamic analysis. In this study, the structural responses of nonlinear static procedure (NSP) based on standard 2800 were compared with ASCE 41-13 code and displacement -based adaptive pushover (DAP) method in three models of reinforced concrete structures including the 3, 7 and 10 story with medium ductility. In order to study the accuracy of nonlinear static analysis and seismic behavior of structures, nonlinear time history analysis (NTHA) which is the most accurate method in seismic assessment of structures was conducted.<br />The results show that in 3 and 10 story the NSP according to standard 2800 with forces distribution obtained from the spectral dynamical analysis is more accurate than other NSPs in evaluating of story drifts ratio and maximum displacement along the height of buildings. In 7 story, displacement -based adaptive pushover (DAP) method can be estimated story drift ratio more precisely. In 3 and 10 story, the NSP based on 2800 with forces distribution obtained from the spectral dynamical analysis, can estimate the mean story drifts with a lower percentage error. According to the results, in each three model the uniform distribution of nonlinear static procedure (NSP) based on standard 2800 estimates the story drifts with less accuracy and high error. As a suggestion, nonlinear static analysis based on uniform distribution can be eliminated from the standard 2800.یکی از روشهای ساده شده که هر روز در حال پیشرفت و تکمیل شدن است آنالیز استاتیکی غیرخطی است که قابلیت ارزیابی مستقیم عملکرد سازه در هر حالت حدی و ارائه اطلاعات از رفتار غیرخطی سازه را دارا بوده و در عین حال پیچیدگیهای آنالیز دینامیکی غیر-خطی را ندارد. در این مطالعه پاسخ سازهای روش تحلیل استاتیکی غیرخطی استاندارد 2800، با آییننامه ASCE/SEI 41-13 آمریکا و روش پوشآور بهنگام شونده بر اساس جابجایی (DAP) در سه مدل ساختمان بتن آرمه 3، 7 و 10 طبقه با شکل پذیری متوسط مورد مقایسه قرار گرفته است. به منظور بررسی دقت روشهای تحلیل استاتیکی غیرخطی و رفتار لرزهای سازهها، تحلیل تاریخچه زمانی غیرخطی (NTHA) که دقیقترین روش برای ارزیابی نیازهای لرزهای سازهها تحت اثر شتابنگاشتهای حرکت زمین است، با استفاده از 7 رکورد زلزله حوزه دور برای هر سازه انجام شده است. نتایج حاصل از این تحقیق بیانگر آن است که در سازه 3 و 10 طبقه، دقت روش تحلیل استاتیکی غیرخطی استاندارد 2800 با توزیع نیروهای حاصل از تحلیل دینامیکی طیفی در تخمین جابجایی طبقات و جابجایی نسبی طبقه نسبت به روش تحلیل دینامیکی تاریخچه زمانی غیرخطی بیشتر میباشد. برای سازه 7 طبقه، روش پوشآور با الگوی بار بهنگام شونده بر اساس جابجایی، بیشترین دقت را بین روشهای تحلیل استاتیکی غیرخطی کلاسیک در تخمین پارامترهای جابجایی نسبی طبقات به خود اختصاص داده است. در سازه 3 و 10 طبقه روش تحلیل استاتیکی غیرخطی استاندارد 2800 با توزیع متناسب با نیروهای حاصل از تحلیل دینامیکی طیفی با درصد خطای کمتری، متوسط جابجایی نسبی طبقات را تخمین میزند. همچنین روش تحلیل استاتیکی غیرخطی استاندارد 2800 با توزیع یکنواخت متناسب با جرم طبقات در هر سه مدل سازه از دقت مناسبی برای تخمین جابجایی نسبی طبقات برخوردار نمیباشد و میتواند از استاندراد 2800 برای سازههای منظم حذف شودhttps://www.jsce.ir/article_85709_8c81d5b32235ca181646254ecf569416.pdfانجمن مهندسی سازه ایرانمهندسی سازه و ساخت2476-39778120210321Effect of different transverse bars arrangements on the behavior of concrete columns under impact loadingتأثیر آرایشهای مختلف میلگردهای عرضی بر رفتار ستونهای بتنی در بارگذاری ناگهانی2202358613110.22065/jsce.2019.159276.1737FAغلامرضا نوریهیات علمی گروه عمران، دانشکده فنی و مهندسی، دانشگاه خوارزمی،0000-0002-2936-599Xجمال برماهگروه عمران، دانشکده فنی و مهندسی، دانشگاه خوارزمی،تهران، ایرانعلی معصومیاستاد و رییس دانشکده فنی و مهندسی / دانشگاه خوارزمی0000-0003-4636-6553Journal Article20181214Due to the fact that common structures are designed only against gravity and seismic loads, the performance of these structures must be investigated against impact loading, in order to protect against this damage if necessary. In this paper, the effect of the arrangement of different shape of transverse bars and their spacing on the performance of beam-column element against blast loading has been studied. In this study, 13 model of concrete beam-column element with different transverse bar arrangement has been explored to examine their performance against explosions with 25 kg TNT. The finite element modeling was performed in Autodyn software and the parameters of explosion modeling, behavioral models of concrete elements and rebar, air meshing dimensions and concrete elements were determined with the results of the field test of explosion in previous studies. In this research, five type of transverse bars shape were modeled proportional to the three spacing of transverse bars. The degree of deformation and the mode of failure of the elements were compared as a measure of the performance of different states of each other. The results showed that for constant area of rebar, the element with one square tie and one link has best performance comparing to other arrangements. The maximum deformation rate in the A-1 (with one square tie ) model was 65 mm and in the D-2 model (one square tie and one link), it was 26 mm, showing a decrease of 60%.با توجه به اینکه سازههای معمول فقط در برابر بارهای ثقلی و لرزهای طراحی میشوند، نیاز است عملکرد این سازهها در برابر بارگذاریهای سریع نیز موردبررسی قرار گیرد تا در صورت لزوم در برابر این آسیب مقاوم و محافظت شوند. در این مقاله اثر آرایش میلگردهای عرضی و فواصل آنها بر عملکرد المانهای تیر- ستون در برابر بار انفجاری مطالعه شده است. بدین منظور 13 مدل مختلف با آرایش میلگردهای عرضی متفاوت تحت انفجار نزدیک با 25 کیلوگرم TNT قرار گرفت. مدلسازی به روش اجزا محدود در نرمافزار اتوداین (Autodyn) انجام شد و پارامترهای مدلسازی انفجار، مدلهای رفتاری المان بتنی و میلگردها، ابعاد مش بندی هوا و المان بتنی از مقایسه نتایج عددی با نتایج آزمایش میدانی انفجار در مطالعات پیشین تعیین و صحت سنجی شدند. در این پژوهش پنج تیپ آرایش میلگرد عرضی متناسب با فواصل خاموتها و 3 نوع شکل خاموت گذاری مدلسازی شدند. برای آرایش خاموتها، خاموت مربعی، خاموت مربعی همراه با سنجاق و خاموت مربعی همراه خاموت لوزی شکل استفاده شد. میزان تغییر شکل و نحوه خرابی المانها بهعنوان معیار عملکرد حالتهای مختلف باهم دیگر مقایسه شدند. نتایج نشان داد به ازای مقدار آرماتور ثابت، المان تیر –ستون با خاموت مربعی همراه با سنجاق، تغییر شکل کمتر و عملکرد بهتری نسبت به سایر آرایشهای خاموت عرضی دارد، بهطوری که میزان حداکثر تغییر شکل در مدل A-1 (خاموت مربعی) 65 میلیمتر و در مدل D-2 (خاموت مربعی همراه با سنجاق)، 26 میلیمتر بهدستآمده است که کاهش 60 درصدی را نشان میدهد و همچنین خرابی در طول المان برای مدل D-2 مشاهده نمیشود.https://www.jsce.ir/article_86131_0179f796c30f3812bf6b4cca1194182d.pdfانجمن مهندسی سازه ایرانمهندسی سازه و ساخت2476-39778120210321Evaluation of the Design Procedures of the Linked Column Frame System and improving its Seismic Behavior using Double Linked Column Patternارزیابی روش های طراحی سیستم قاب با ستون پیوند شده و بهبود رفتار لرزه ای آن با آرایش ستون پیوند دوتایی23625510697710.22065/jsce.2020.223180.2103FAالهام معروفیدانشجوی دکتری مهندسی سازه، گروه مهندسی عمران، واحد علوم و تحقیقات، دانشگاه آزاد اسلامی، تهران، ایران0000-0002-3486-2835محمد رضا منصوریاستادیار، گروه مهندسی عمران ، واحد علوم و تحقیقات، دانشگاه آزاد اسلامی ، تهران، ایران0000-0003-3895-6326عبدالرضا سروقد مقدمدانشیار، پژوهشگاه بین المللی زلزله شناسی و مهندسی زلزله، تهران، ایران0000-0002-3831-8757آرمین عظیمی نژاداستادیار، گروه مهندسی عمران ، واحد علوم و تحقیقات، دانشگاه آزاد اسلامی ، تهران، ایران0000-0001-9973-1361Journal Article20200311The linked column frame (LCF) as a seismic resistant system with the ductile behavior using shear fuse will reduce the damage to other members of the structure at different hazard levels. In this paper, the seismic behavior of the LCF systems designed by Shoaib and Malakoutian procedures has been evaluated. In order to improve the seismic performance of the designed samples, a new and optimal system with the pattern of the double linked columns has been proposed. For this purpose, a 3-story model of SAC buildings with two linked beam bays and four- moment frame bays has been designed by the procedures. The studied models include: 1-The model designed by Malakoutian procedure (MaM), 2- The model designed by Shoaib procedure (ShM) and 3- The LCF with double-linked column pattern (DLCF). Models have been evaluated using incremental dynamic analyses according to FEMAP695 instructions in OPENSEES. The results show that the model designed by Shoaib procedure (ShM) has “50%” and 14% more capacity than the model designed by Malakoutian procedure and the DLCF model respectively. Also the average link beam capacity in the ShM model is “50%” higher than the MaM model. Finally the results show that compared to the MaM model the new pattern of the linked column in the DLCF model has considerably increased the structure’s capacity, the link beam capacity in energy absorption and base shear capacity by an average of 30%.سیستم قاب با ستون پیوند شده به عنوان یک سیستم باربر لرزه ای مقاوم، با رفتار تیرپیوند شکل پذیر به عنوان فیوز برشی، در سطوح مختلف خطر سبب کاهش و یا عدم آسیب در دیگر اعضاء سازه خواهد شد. در این مقاله به ارزیابی لرزه ای روش های طراحی سیستم قاب با ستون پیوند شده فولادی پرداخته شده است.در ادامه تحقیق به هدف بهبود عملکرد لرزه ای نمونه های طراحی شده، سیستم جدید و بهینه ای با آرایش قرار گیری ستون پیوند شده دوتایی پیشنهاد شده است. به همین منظور مدل 3 طبقه از مد لهای SAC با 2 دهانه تیر پیوند و 4 دهانه قاب خمشی به دو روش پیشنهادی شعیبی و ملکوتیان طراحی شده است. مدل ها به سه شکل مورد مطالعه قرار گرفته است : 1- مدل طراحی شده به روش طراحی ملکوتیان (MaM) 2-مدل طراحی شده به روش طراحی شعیبی (ShM)3- مدل قاب با ستون پیوند شده با آرایش دوتایی (DLCF)..مدل ها تحت تحلیل دینامیکی فزاینده طبق دستور العمل FEMAP695 در نرم افزارOPENSEES مورد ارزیابی قرار گرفته است. نتایج نشان داد که مدل طراحی شده به روش شعیبی (ShM) به طور متوسط 50 درصد ظرفیت بیشتری نسبت به مدل طراحی شده به روش ملکوتیان (MaM) دارد و به طور متوسط 14درصد ظرفیت بیشتری نسبت به مدل DLCF دارد.در انتها نتایج نشان می دهد تغییر آرایش قرار گیری ستون پیوند در مدل DLCF به طور متوسط باعث افزایش 23 درصدی ظرفیت سازه ،ظرفیت تیرپیوند در جذب انرژی و ظرفیت برش پایه نسبت به مدلMaM شده استhttps://www.jsce.ir/article_106977_11437632213a4478c0c4110a68a32e65.pdfانجمن مهندسی سازه ایرانمهندسی سازه و ساخت2476-39778120210321A study on compressive strength, static and dynamic elastic modulus of self-compacted concrete contained nanomaterialsمطالعهای بر مقاومت فشاری، مدول الاستیسیته استاتیکی و دینامیکی بتنهای خودتراکم حاوی نانو مواد2562708616410.22065/jsce.2019.155039.1700FAرحمت مدندوستگروه عمران- دانشکده فنی-دانشگاه گیلان-رشتصابر دیلمی پشتجوئیکارشناسی ارشد عمران گرایش سازه، دانشگاه گیلان، ایرانJournal Article20181105In this study, the influence of different kinds of nanomaterials such as Nano oxides of Silica (NS), Aluminum (NA) and Copper (NC) on compressive strength (f’c), static elastic modulus (Ee), relationship between f’c and Ee and the relationship between static and dynamic elastic modulus (Ed) of self-compacted concrete are examined. The nanomaterials are used as the binder in replacement of Portland cement. For this purpose, standard cylindrical samples containing NS, NA and NC with amounts of 1.5, 0.25 and 0.25%, respectively, were tested between 3 and 90 days. The f’c, Ee and Ed are evaluated according to ASTM C39/39M-16b, ASTM C469/C469M-14 and ASTM C597-16, respectively. Results indicate that adding Nanomaterials lead to improvement of f’c and elasticity module. New relations between f’c and Ee and, also, linear relation between Ee and Ed defined for this kind of self-compacted concretes, and it was observed that type and quantity of the Nanomaterials have impact on these relations. The experimental data of Ee at early ages are smaller than the calculated values of Ee from recommended equations by ACI 318-14, ACI 363-10, and CSA A23.3-14. The difference between experimental data and calculated values of Ee is decreased when f’c increases. when the f’c is higher than 45 MPa, the experimental data of Ee are higher than the calculated values of ACI 363-10. The study indicate that the Ed is always greater than the Ee and the difference between Ed and Ee is decreased when f’c increases. It was found that the differences between Ed and Ee in this study are greater than the differences between Ed and Ee in BS 8110: 2 and the other studies.در این مطالعه تأثیر انواع نانو مواد نظیر نانو اکسیدهای سیلیس (NS)، آلومینیوم (NA) و مس (NC) بر مقاومت فشاری (f’c)، مدول الاستیسیته استاتیکی(Ee)، رابطه f’c - Ee و رابطه مدول الاستیسیته استاتیکی و دینامیکی (Ed) در بتنهای خودتراکم بررسی گردید. نانو مواد مذکور به عنوان ماده چسباننده جایگزین بخشی از وزن سیمان استفاده شدند. برای این منظور نمونههای استوانهای استاندارد حاوی NS، NA و NC به ترتیب با مقادیر 5/1، 25/0 و 25/0 درصد، در سنین بین ۳ تا ۹۰ روز تحت آزمایشهای f’c مطابق ASTM C39/39M-16b، Ee مطابق ASTM C469/c469M-14 و Ed مطابق ASTM C597-16 قرار گرفتند. نتایچ نشان داد که افزودن نانو مواد باعث بهبود مقاومت فشاری و مدول الاستیسیته گردید. روابطی جدید بین مقاومت فشاری و Ee و همچنین روابطی خطی میان Ee و Ed برای این نوع بتنهای خودتراکم تعریف شد و مشاهده شد که نوع و مقدار نانو مواد، فارق از نوع آن، بر این روابط اثر گذار است. در سنین اولیه Ee اندازه گیری شده کمتر از Ee محاسبه شده از آییننامههای ACI 318-14، ACI 363-10 و CSA A23.3-14 است اما با افزایش مقاومت اختلاف میان این دو کاهش یافت و به نظر میرسد که در مقاومتهای بالاتر از ۴۵ مگاپاسکال Ee تخمین زده شده در این مطالعه بیشتر از Ee محاسبه شده از رابطه ACI 363-10 است. همواره Ed از Ee بیشتر است و با افزایش مقاومت اختلاف آنها کاهش مییابد. همچنین مشاهده گردید که اختلاف میان Ee و Ed در بتنهای خودتراکم این مطالعه بیشتر از اختلاف آنها در روابط پیشنهادی آییننامه 2 BS 8110: Part و مطالعات گذشته است.https://www.jsce.ir/article_86164_bd094e52eee1457e60445f527d081004.pdfانجمن مهندسی سازه ایرانمهندسی سازه و ساخت2476-39778120210321Seismic Vulnerability Assessment of Retrofitted Steel Structures with Fractional Viscoelastic Dampers Considering Uncertainty Variablesارزیابی آسیب پذیری لرزهای سازه فولادی مقاومسازی شده با میراگر مشتق کسری با لحاظ متغیرهای غیرقطعی2712858763410.22065/jsce.2019.171919.1785FAمریم بهشتیدانشآموخته کارشناسی ارشد مهندسی سازه، دانشکده مهندسی عمران، دانشگاه صنعتی اصقهان، اصفهان، ایرانپیام اسدیاستادیار، دانشکده مهندسی عمران، دانشگاه صنعتی اصفهان، اصفهان، ایران0000-0003-3477-7777Journal Article20190213Using viscoelastic (VE) dampers is one of the most effective tools for seismic retrofitting of steel structures. The results of many experimental studies demonstrated that using fractional derivative terms for modelling viscoelastic dampers offers an acceptable level of accuracy. Unlike viscous dampers the damping force is not linearly dependent to velocity and it is also highly affected by excitation frequency and ambient temperature. For this reason, solving the dynamic equation and calculating the seismic response of the structures equipped with VE dampers have many complexities. In this paper, the responses of a viscoelastically damped structure are calculated and the seismic performance of the building is evaluated while considering the effects ambient temperature as well as the inherent uncertainties related to ground motion excitation. <br />The proposed relationships were used to calculate the structural responses and assess the seismic performance of a 5-story steel structure retrofitted with fractional viscoelastic dampers. The maximum relative displacement of the controlled structural at the operation, design, and maximum considered expected hazard levels were compared to those of the initial structure (without damper). Furthermore, fragility curves were used to compare responses and exceedance probabilities of performance limit states. The results show great improvement in structural seismic performance related to the reduction of both structural responses and exceedance probabilities of limit states. The effect of temperature changes in results has been also demonstrated.استفاده از میراگرهای ویسکوالاستیک یکی از موثرترین راهکارها برای مقاومسازی لرزهای سازهها هستند. نتایج بسیاری از مطالعات آزمایشگاهی نشان داده است که مدلهای مشتق کسری برای مدلسازی میراگرهای ویسکوالاستیک دارای دقت بسیار بالایی بوده است. نیروی میراگر ویسکوز تنها دارای رابطه خطی با سرعت است، اما نیروی میراگر ویسکوالاستیک مشتق کسری ، علاوه بر این که رابطه خطی با سرعت ندارد، به مقادیر فرکانس تحریک و دمای محیط نیز مرتبط است. همچنین معادله دینامیکی سازه مجهز به این نوع میراگرها و محاسبه پاسخ این سازهها تحت تحریک زلزله، دارای پیچیدگیهای بسیاری است. در این مقاله پاسخهای سازههای مجهز به این نوع میراگرها، محاسبه شده و ارزیابی لرزهای آنها با توجه به تغییرات دمای محیط و همچنین تصادفی بودن شتابنگاشت تحریک، انجام شده است. معادلات ارائه شده برای سازه فولادی 5 طبقهای که با میراگرهای ویسکوالاستیک دارای رفتار مشتق کسری ، مقاومسازی شدهاست، به کار گرفته شده است. مقادیر حداکثر جابجایی نسبی طبقهای سازه کنترل شده در سطوح خطر زلزله بهرهبرداری، طرح و حداکثر با سازه اولیه مقایسه شده و همچنین با توجه به تصادفی بودن تحریکها از منحنی شگنندگی برای مقایسه پاسخها استفاده شده است. نتایج نشان داده است، که این میراگرها مقادیر پاسخ سازهها در برابر زلزله و احتمال فراگذشت از حدود عملکردی را کاهش دادهاند. همچنین تغییرات دما در تغییر مقادیر پاسخها بسیار موثر بوده است.https://www.jsce.ir/article_87634_b127a2604c2c614b035eb9a60480c7fc.pdfانجمن مهندسی سازه ایرانمهندسی سازه و ساخت2476-39778120210321The high modes of structure effect on the seismic demands of hollow brick partitionsمطالعه اثر مودهای بالای سازه بر نیازهای لرزه ای تیغه های آجری مجوف2863068763510.22065/jsce.2019.176038.1806FAعلیرضا کازرونیانمربی، گروه مهندسی عمران، دانشکده مهندسی، دانشگاه آزاد اسلامی، بوشهر، ایرانمحمدتقی کاظمیدانشیار، دانشکده مهندسی عمران، دانشگاه صنعتی شریف، تهران، ایرانJournal Article20190313Observations from past earthquakes in reinforced concrete buildings show that the masonry partitions can endanger the life of buildings occupants and lead to significant damage and loss. The most present codes of practice do not consider the effects of nonlinearity and higher modes of the structure and three-dimensional behavior of partitions on the out-of-plane seismic demands of these components simultaneously and the main purpose of this study is to investigate the effect of these cases together. This research involves assessing the seismic performance of partitions made of the hollow brick located in different stories of 3-, 7- and 11-story buildings containing 3D reinforced concrete special moment frames and subjected to a suite of 7 appropriate earthquakes. A finite element program, OpenSees, has been used for nonlinear seismic response history analysis. The average of the peak of responses of partition, under the seismic excitations, was computed for any model and the forces obtained using the analytical method, which some of them verified with existing studies results, were compared with the values from the code. For the majority of the models, the results show that the analytical seismic demands on partitions, in the lower half, are higher than those calculated using the code provisions because of the effect of higher modes of the structures and the peak values is even up to 1.54 times the computed value based on the code. The code provisions are conservative for the partitions in the upper half of the buildings.مشاهدات از زلزلههای گذشته در ساختمانهای بتن مسلح نشان میدهد که تیغههای جداکننده بنایی میتوانند زندگی ساکنان را به خطر انداخته و منجر به آسیب و زیان قابل توجهی شوند. اکثر آئیننامههای کنونی، اثرات غیرخطی و مودهای بالاتر سازه و رفتار سه بعدی تیغهها را بر روی نیازهای لرزهای خارج از صفحه این اجزا به طور همزمان در نظر نمیگیرند و هدف اصلی این پژوهش بررسی اثر این موارد به صورت توأم میباشد. در این تحقیق عملکرد لرزهای تیغههای ساخته شده از آجر مجوف و مستقر در طبقات مختلف ساختمانهای 3، 7 و 11 طبقه با قابهای سه بعدی خمشی بتن مسلح ویژه و تحت تاثیر مجموعهای از 7 زلزله مناسب مورد ارزیابی قرار گرفته است. از برنامه اجزای محدود OpenSees جهت تحلیل غیرخطی تاریخچه پاسخ لرزهای استفاده شده است. برای هر نمونه، میانگین حداکثر پاسخهای تیغه ناشی از تحریکهای لرزهای محاسبه و این نیروهای حاصل از تحلیل، که بعضی از آنها با نتایج مطالعات موجود صحت سنجی شدهاند، با مقادیر آئیننامه مقایسه شدند. نتایج نشان میدهد که در اکثر نمونهها به علت تاثیر مودهای بالاتر سازهها، نیازهای لرزهای تحلیلی تیغههای واقع در نیمه پایینی بیشتر از مقادیر حاصل از ضوابط آئیننامه بوده و حداکثر آنها حتی تا 54/1 برابر مقدار محاسبه شده بر اساس آئیننامه میباشد. ضوابط آئیننامه برای تیغههای واقع در نیمه فوقانی ساختمانها به صورت محافظه کارانه میباشند.https://www.jsce.ir/article_87635_8f6e20f0c986b674a3c51aa57d932cbf.pdfانجمن مهندسی سازه ایرانمهندسی سازه و ساخت2476-39778120210321An investigation on the bearing capacity of piled raft foundations experimentally and comparison with modified hyperbolic model resultsبررسی آزمایشگاهی ظرفیت باربری پی رادیه شمع و مقایسه با نتایج مدل هایپربولیک اصلاحشده3073268812210.22065/jsce.2019.171280.1779FAمحمد جمال ملک خانیدانشجوی دکتری خاک و پی، گروه مهندسی عمران، دانشکده مهندسی، دانشگاه فردوسی مشهد، ایرانجعفر بلوری بزازدانشیار، گروه مهندسی عمران، دانشکده مهندسی، دانشگاه فردوسی مشهد، ایران0000-0002-5106-1845Journal Article20190207Because of non-linear and settlement dependent behavior of soil and effect of the interactions, understanding the behavior of piles and raft and the load sharing mechanism in piled rafts is a key issue. Recently, researchers have introduced few normalized hyperbolic models according to numerical analysis to estimate the load-sharing ratio of piles in piled raft foundations. These models are based on experimental results and considering different interaction effects between pile-raft-soil, raft, and pile dimensions and the amount of settlement. The aim of this research is to investigate the behavior of piled raft foundation and to estimate the load-sharing ratio of piles experimentally. So, various tests have been conducted on piled rafts, group piles, and unpiled rafts under vertical loading by changing the number and length of piles and density of bed sand. For this purpose, an innovative combined loading system, instrumented by measuring devices, is designed and constructed; then the load-sharing ratio of piles from the total load with a novel method is estimated by measuring soil pressure underneath the raft at any settlement. According to the results, bearing capacity of piled raft foundation in analogous conditions is more than unpiled raft and twice group piles approximately. Also increasing the number of piles in piled rafts and group piles increases bearing capacity and reduces raft settlement. The load sharing ratio of piles shows downward trend by increasing settlement and it increases with increasing the number of piles in the same conditions. In this study, the ultimate bearing capacity of group piles which have been experimentally obtained is compared with the ultimate criterion of the hyperbolic model proposed by other researchers. Then, the model is modified by mathematical analysis methods indicating good agreement between experimental and analytical results.شناخت رفتار و نحوه توزیع بار بین شمع و پی در پی رادیه شمع به دلیل رفتار غیرخطی و وابسته به نشست و نیز وجود پیچیدگیهای ناشی از اندرکنشها مساًلهای کلیدی میباشد. اخیراً پژوهشگران مدلهایی را برای تخمین نسبت سهم باربری شمعها در پی رادیه شمع بر مبنای تحلیلهای عددی به فرم معادله هایپربولیک نرمالیزه شده ارائه کردهاند. این مدلها بر اساس نتایج آزمایشگاهی و با لحاظ نمودن اثر اندرکنشهای مختلف بین شمع-پی-خاک، ابعاد پی و شمع و مقدار نشست سطحی پی میباشند. هدف انجام پژوهش حاضر بررسی رفتار پی رادیه شمع و تعیین سهم باربری شمعها در این سیستم به روش آزمایشگاهی میباشد. بنابراین با تغییر تعداد و طول شمعها و تراکم ماسه بستر، آزمایشهایی تحت بار قائم بر روی پی رادیه شمع، گروه شمع و پی بدون شمع انجامشده است. به این منظور سیستم بارگذاری ترکیبی ابداعی با بهرهگیری از ابزار دقیق طراحی و ساخته شد و سپس سهم باربری شمعها به روشی نوین با اندازهگیری فشار خاک زیر پی در هر مقدار نشست و با توجه به کل بار وارده محاسبهشده است. بر اساس نتایج بهدستآمده، ظرفیت باربری پی رادیه شمع در حالت مشابه بیش از پی سطحی و تقریباً دو برابر گروه شمع میباشد. همچنین افزایش تعداد شمع در پی رادیه شمع و گروه شمع باعث بهبود ظرفیت باربری خاک و کاهش نشست میگردد. نسبت سهم باربری شمعها با افزایش مقدار نشست سطحی روند نزولی دارد که این سهم با افزایش تعداد شمعها در حالت مشابه افزایشیافته است. در این پژوهش ظرفیت باربری نهایی گروه شمعها که بهصورت آزمایشگاهی بهدستآمده با معیار بیانشده در مدل هایپربولیک پیشنهادی توسط سایر محققین مقایسه شده است. سپس مدل مزبور با استفاده از روشهای محاسباتی تصحیح گشته که بیانگر انطباق خوبی بین نتایج آزمایشگاهی و تحلیلی میباشد.https://www.jsce.ir/article_88122_ebc19233f4d173c2232d95ca0724b132.pdfانجمن مهندسی سازه ایرانمهندسی سازه و ساخت2476-39778120210321Effects of plastic hinges modelling of fully restrained connections in the progressive collapse resistance of steel moment framesاثرات مدل سازی مفاصل پلاستیک اتصالات صلب بر مقاومت خرابی پیشرونده قاب های خمشی فولادی3273428812310.22065/jsce.2019.184813.1855FAمحمد سقای صاحب الزمانکارشناسی ارشد، مهندسی عمران- سازه ، دانشکده فنی و مهندسی، دانشگاه ارومیه ، ارومیه، ایرانمحمد رضا شیداییاستاد، دانشکده فنی و مهندسی، دانشگاه ارومیه، ارومیه، ایران0000-0002-9606-0205علیرضا سلماسیدانشجوی دکتری، مهندسی عمران – سازه، دانشکده فنی و مهندسی، دانشگاه ارومیه، ارومیه، ایرانJournal Article20190508Nowadays, the using of steel moment frames has been considered as an effective lateral load-resisting system against seismic forces. In this research, the effect of plastic hinges modelling of fully restrained connections has been evaluated on the strength of steel moment frame structures against progressive collapse. In order to assessment of the progressive collapse performance of sample structures, two structural models of 3 and 5-story buildings were designed and then the definition and modelling of plastic hinges have been done in two different modes. In the first mode, plastic hinges were modelled only for the beam and column members. In the second mode, plastic hinges were considered for the connections in addition to the beam and column members. The Five different types of investigated connections included WFP, WBH, WCPinWUF, WUF-B, Welded top and bottom haunch. The progressive collapse resistance of these buildings against sudden removal of internal and external column was separately studied using nonlinear static alternate path method presented in the UFC standard. The results of analysis indicated that if the plastic hinges of connections are separately defined in addition to the plastic hinges of beams and columns, the structure will have lower progressive collapse strength, and the resistance of the structure tends to its actual value. Simultaneous modelling of plastic hinges for connections and members at least 20% and maximum 37% affects the reduction of structural strength against progreive collapse. Therefore, the modelling of plastic hinges for connections and members simultaneously should be considered as a important regulation. According to the comparative results, the WCPinWUF and WUF-B connection respectively demonstrated that the most desirable behaviour and the weakest performance against the progressive collapses.امروزه استفاده از سیستم های قاب خمشی فولادی به عنوان یک سیستم باربر جانبی کارآمد در برابر نیروهای لرزه ای مورد توجه قرار گرفته است. در این مطالعه تاثیر مدل سازی مفاصل پلاستیک اتصالات صلب بر مقاومت سازه های قاب خمشی فولادی در برابر خرابی پیشرونده بررسی شده است. برای مطالعه رفتار خرابی پیشرونده ساختمان های نمونه، دو مدل سازه 3 و 5 طبقه طراحی شده و سپس تعریف و مدل سازی مفاصل پلاستیک در دو حالت مختلف انجام شده است. در حالت اول مفاصل پلاستیک صرفا برای اعضای تیر و ستون مدل سازی شدند و در حالت دوم مفاصل پلاستیک علاوه بر اعضای تیر و ستون برای اتصالات نیز در نظر گرفته شده اند. اتصالات بررسی شده شامل پنج نوع مختلف اتصال صلب شامل WFP ، WBH، WCPinWUF، WUF-B و Welded top and bottom haunch بودند. ارزیابی پتانسیل خرابی پیشرونده سازه های مذکور به ازای حذف ستون های پیرامونی و داخلی به روش مسیر جایگزین استاتیکی غیرخطی مطابق آیین نامه UFC انجام گرفته است. نتایج تجزیه و تحلیل ها نشان می دهند که با تعریف و اعمال همزمان مفاصل پلاستیک در محل اتصالات و اعضای تیر و ستون، سازه مقاومت کمتری در برابر خرابی پیشرونده از خود نشان می دهد و مقاومت سازه به مقدار واقعی خود نزدیک تر می شود. مدل سازی همزمان مفاصل پلاستیک برای اتصالات و اعضا در کمترین حالت 20% و در بیشترین حالت 37% بر روی کاهش مقاومت سازه در برابر خرابی پیشرونده تاثیر می گذارد. لذا مدل سازی مفاصل پلاستیک اتصالات و اعضا به صورت همزمان باید به عنوان یک اصل بسیار مهم در نظر گرفته شود. با توجه به نتایج مقایسه ای می توان نتیجه گرفت که اتصال WCPinWUF و WUF-B به ترتیب بهترین رفتار و ضعیف ترین عملکرد را نسبت به سایر اتصالات در برابر خرابی پیشرونده نشان می دهند.https://www.jsce.ir/article_88123_690b25e993b6f00dc87783ff392f2c0b.pdf