<ArticleTitle>Structural behaviour of concrete poles used in electric&#039;s power distribution network</ArticleTitle>
<VernacularTitle>ارزیابی رفتار سازه ای پایه های بتنی شبکه توزیع برق</VernacularTitle>
			<FirstPage>29</FirstPage>
			<LastPage>41</LastPage>
			<ELocationID EIdType="pii">44439</ELocationID>
			
<ELocationID EIdType="doi">10.22065/jsce.2017.44439</ELocationID>
			
			<Language>FA</Language>
<AuthorList>
<Author>
					<FirstName>مهران</FirstName>
					<LastName>زینلیان</LastName>
<Affiliation>استادیار، دانشکده مهندسی عمران و حمل و نقل، دانشگاه اصفهان، ایران</Affiliation>
<Identifier Source="ORCID">0000-0002-0681-2654</Identifier>

</Author>
<Author>
					<FirstName>مهرداد</FirstName>
					<LastName>زمانی خوراسگانی</LastName>
<Affiliation>کارشناس ارشد مهندسی عمران، دانشکده مهندسی عمران و حمل و نقل، دانشگاه اصفهان، ایران</Affiliation>

</Author>
</AuthorList>
				<PublicationType>Journal Article</PublicationType>
			<History>
				<PubDate PubStatus="received">
					<Year>2016</Year>
					<Month>11</Month>
					<Day>10</Day>
				</PubDate>
			</History>
		<Abstract>Based on a preliminary study on regional electric companies, it is shown that there is no precise structural design on the concrete poles. This leads to uneconomical and overestimated networks’ components. Therefore, this study was aimed to investigate the lateral performance of the concrete poles which are employed in electric’s power distribution network. This paper presents a numerical study on structural performance of 12 m concrete poles used in electric’s power distribution network using Abaqus software. A sensitivity study for mesh size is carried out and concrete damaged plasticity has been employed. The results show that relatively coarse mesh (average) in damaged concrete method gives more reliable result. Some experimental tests based on the Iranian standards were performed in order to make a bench mark for numerical output. Comparison between numerical and experimental results indicates a good agreement between the results. The outcomes also suggest that while the applied lateral load is less than around 400 kg which is assumed as the nominal resistance of the pole, no transverse crack occurs. Based on both experimental and numerical results, one or two transverse cracks are reported when the applied force reaches up to 600 kg. The rate of cracks is amplified by increasing the applied force; and finally, the pole would lose its capacity when the load rises much more than 1200 kg. The study also shows that the poles are very weak when the load direction changes. Also, it can be concluded that the final strength of the pole is higher than what the standards recommend. Finally, seismic behavior factor of the poles around both main axes are evaluated. The estimated seismic resistance factor for the concrete poles indicates that the prescribed R factor for such structure is relatively low; and can be improved at least 20%.</Abstract>
			<OtherAbstract Language="FA">خطوط شبکه توزیع برق یکی از مراحل رسیدن برق از تولید کننده به مصرف کننده می‌باشد که طراحی اصولی آن، موجب پایداری شبکه و جلوگیری از تحمیل هزینه های اضافه می‌شود. یکی از پرکاربردترین اجزاء شبکه توزیع برق، پایه های بتنی H شکل می باشد که عملکرد مطلوب سازه ای آنها از اهمیت ویژه ای برخوردار است. در این مقاله، ضمن ارائه و بررسی نتایج آزمایش در مقیاس واقعی بر روی پایه های متداول مورد استفاده در شبکه های توزیع برق (پایه 12 متری با قدرت اسمی400 کیلوگرم)،  به بررسی عددی آن با استفاده از برنامه ی اجزای محدود آباکوس پرداخته شده است و نحوه شکست و ضریب رفتار لرزه ای در آن مورد بررسی قرار گرفته است. به منظور ایجاد شرایط واقعی برای بتن پایه از روش پلاستیسیته بتن خسارت دیده و از قید مدفون سازی نیز جهت ارتباط بتن و میلگرد استفاده شده است. مقایسه نتایج عددی و آزمایشگاهی، بیانگر انطباق مناسب مدل عددی با نتایج آزمایشگاهی است. نتایج بررسیهای صورت گرفته، نشانگر ظرفیت بالاتر پایه های موجود از ظرفیت ارائه شده در آیین نامه ایران می‌باشد. ضریب رفتار بدست آمده نیز، بیانگر شکل پذیری مناسب این پایه ها بوده و نشان می دهد که مقادیر توصیه شده توسط آیین نامه می‌تواند بصورت قابل ملاحظه ای افزایش یابند؛ این موضوع، می‌تواند باعث استفاده از پایه های با ظرفیت کمتر شود که در نهایت کاهش هزینه های احداث شبکه های توزیع برق کشور را در پی خواهد داشت.</OtherAbstract>
		<ObjectList>
			<Object Type="keyword">
			<Param Name="value">شبکه توزیع برق</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">پایه های بتنی</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">اجزا محدود</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">ضریب رفتار</Param>
			</Object>
		</ObjectList>
<ArchiveCopySource DocType="pdf">https://www.jsce.ir/article_44439_22242fffb164c888879c3513a550427b.pdf</ArchiveCopySource>
</Article>
</ArticleSet>