<ArticleTitle>Investigation of out-of-plane behavior of non-bearing masonry walls reinforced with cement matrix and fiber</ArticleTitle>
<VernacularTitle>بررسی رفتار لرزه‌ای خارج صفحة دیوارهای بنایی غیر باربر مسلح شده توسط کامپوزیت سیمانی الیاف‌دار</VernacularTitle>
			<FirstPage>80</FirstPage>
			<LastPage>100</LastPage>
			<ELocationID EIdType="pii">228529</ELocationID>
			
<ELocationID EIdType="doi">10.22065/jsce.2025.539686.3794</ELocationID>
			
			<Language>FA</Language>
<AuthorList>
<Author>
					<FirstName>سید علی</FirstName>
					<LastName>رضوی طباطبائی</LastName>
<Affiliation>استادیار، دانشکده‌ فنی مهندسی، دانشگاه علم و فرهنگ، تهران، ایران</Affiliation>
<Identifier Source="ORCID">0000-0002-8061-6213</Identifier>

</Author>
<Author>
					<FirstName>علی</FirstName>
					<LastName>حاجی اکبری</LastName>
<Affiliation>کارشناس ارشد، دانشگاه علم و فرهنگ، تهران، ایران</Affiliation>
<Identifier Source="ORCID">0009-0003-3479-999X</Identifier>

</Author>
<Author>
					<FirstName>محمد</FirstName>
					<LastName>چکاه فر</LastName>
<Affiliation>-دانشجو دکتری عمران سازه، دانشگاه علم و فرهنگ، تهران، ایران</Affiliation>

</Author>
<Author>
					<FirstName>سید مهدی</FirstName>
					<LastName>موسوی</LastName>
<Affiliation>دانشیار، گروه مهندسی عمران، دانشگاه اراک، ایران</Affiliation>

</Author>
</AuthorList>
				<PublicationType>Journal Article</PublicationType>
			<History>
				<PubDate PubStatus="received">
					<Year>2025</Year>
					<Month>08</Month>
					<Day>06</Day>
				</PubDate>
			</History>
		    <Abstract>Infill masonry walls, commonly used as non-structural components in buildings, are highly vulnerable to out-of-plane forces induced by earthquakes. Traditional retrofitting methods, such as the use of steel walers, often face challenges including implementation difficulties, increased structural weight, and architectural incompatibility. This study investigates the out-of-plane seismic performance of non-structural masonry walls using two novel reinforcement techniques: external vertical mesh reinforcement and bed-joint reinforcement with carbon fiber fabrics (FRCM systems). To this end, nine half-scale wall specimens were constructed in three groups control, externally reinforced, and bed-joint reinforced—and tested under cyclic out-of-plane loading using a hydraulic actuator. Evaluated parameters included flexural capacity, initial stiffness, ductility, and response modification factor. Experimental results showed that external vertical mesh reinforcement led to approximately a 302% increase in flexural capacity, while the bed-joint reinforcement method resulted in a 195% improvement compared to the control group. Initial stiffness increased by about 700% and 200% respectively for the two methods, along with notable improvements in ductility and energy dissipation capacity. The comparable seismic performance of the two techniques highlights the practical advantages and reduced technical constraints of the bed-joint method. Overall, the findings suggest that FRCM systems particularly the bed-joint approach offer an effective, lightweight, and practical solution for seismic retrofitting of non-structural masonry walls without adding significant weight or construction complexity.</Abstract>
			<OtherAbstract Language="FA">دیوارهای میان‌قابی بنایی، به‌عنوان عناصر غیرسازه‌ای در بسیاری از ساختمان‌ها، در برابر نیروهای خارج از صفحه ناشی از زلزله بسیار آسیب‌پذیر هستند. روش‌های سنتی مقاوم‌سازی، مانند استفاده از وال‌پست با چالش‌هایی نظیر دشواری اجرا، افزایش وزن و تداخل با معماری مواجه‌اند. در این پژوهش، عملکرد خارج صفحه دیوارهای بنایی غیرسازه‌ای تحت بارگذاری چرخه‌ای، با استفاده از دو تکنیک نوین مقاوم‌سازی شامل تسلیح خارجی با مش قائم و تسلیح میان‌رجی با منسوجات فیبرکربنی (FRCM) بررسی شد. برای این منظور، ۹ نمونه دیوار بنایی در سه گروه شاهد، تقویت‌شده با مش قائم و تقویت‌شده میان‌رجی ساخته شده و تحت بارگذاری چرخه‌ای خارج صفحه قرار گرفتند. پارامترهای مورد ارزیابی شامل ظرفیت خمشی، سختی اولیه، شکل‌پذیری و ضریب رفتار غیرخطی بودند. نتایج نشان داد که تقویت با مش قائم خارجی منجر به افزایش حدود ۳۲۴ درصدی، و روش میان‌رجی حدود ۳۰۵ درصدی در ظرفیت خمشی نسبت به نمونه‌های شاهد شده‌اند. همچنین، سختی اولیه در روش‌های مذکور به ترتیب حدود ۷ و ۱۰ برابر افزایش یافته و ضریب رفتار و شکل‌پذیری نیز بهبود یافته است. اختلاف ناچیز بین عملکرد این دو روش، مزایای اجرایی و کاهش محدودیت‌های فنی در روش میان‌رجی را برجسته می‌کند. یافته‌ها نشان می‌دهند که استفاده از سامانه‌های FRCM، به‌ویژه در حالت میان‌رجی، می‌تواند راهکاری مؤثر، سبک، و قابل‌اجرا برای مقاوم‌سازی لرزه‌ای دیوارهای غیرسازه‌ای بنایی بدون افزایش وزن یا پیچیدگی ساخت باشد.</OtherAbstract>
		<ObjectList>
			<Object Type="keyword">
			<Param Name="value">دیوار بنایی میان‌قابی</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">مقاوم‌سازی لرزه‌ای</Param>
			</Object>
			<Object Type="keyword">
			<Param Name="value">کامپوزیت سیمانی الیاف</Param>