@article { author = {بهشتی اول, سید بهرام and S.Moghadam, Abdolreza and Mohsenian, Vahid}, title = {Seismic Behavior of Tunnel Form Reinforced Concrete Buildings with Mass Irregularity in Elevation}, journal = {Journal of Structural and Construction Engineering}, volume = {5}, number = {شماره ویژه 4}, pages = {5-21}, year = {2019}, publisher = {Iranian Society of Structural Engineering (ISSE)}, issn = {2476-3977}, eissn = {2538-2616}, doi = {10.22065/jsce.2017.78052.1086}, abstract = {Non-uniform mass distribution in elevation is one of the main sources of irregularity in buildings that could lead to concentration of nonlinear deformations followed by local or global damage to buildings during earthquake excitation. Considering lack of accurate information about behavior of tunnel form RC buildings in preceding earthquakes, it is required to evaluate vulnerability of such buildings with mass irregularity in elevation. In this research, seismic behavior of tunnel form RC buildings with heights of 5 and 10 stories, having different patterns of non-uniform mass distributions in elevation is studied in the nonlinear deformation range. For this purpose, seismic performance levels of understudied buildings under design earthquake are determined using time history analysis as well as pushover analysis. Fragility curves are developed by analytical approach for different hazard levels. The results show excellent performance of this structural system and placement in immediate occupancy performance level under maximum design earthquake Iranian seismic code (standard No. 2800). Moreover, modal vibration response of the system is not influenced by building height and height-wise mass distribution pattern. It seems that the provision No. 5 of regulations issued by Road, Housing & Urban Development Research Center of Iran pertaining to design and construction of tunnel form RC buildings, which stipulates that this type of buildings have to be regular in elevation, is so strict and conservative for the studied models with selected patterns of mass irregularities.}, keywords = {Tunnel Form System,performance level,Mass irregularity,Irregularity in elevation,Fragility curves}, title_fa = {رفتار لرزه‌ای ساختمان‌های بتنی قالب‌تونلی با توزیع غیریکنواخت جرم در ارتفاع}, abstract_fa = {توزیع غیریکنواخت جرم در ارتفاع یکی از منابع مهم شکل‌گیری نامنظمی در ساختمان‌ها بوده که حین زلزله می‌تواند منجر به تمرکز تغییرشکل‌های غیرخطی و به دنبال آن خرابی‌های موضعی یا کلی در ساختمان گردد. نظر به کمبود اطلاعات و تجربه رفتار در زلزله‌های قوی ﮔﺬشته در ساختمان‌های بتنی با سیستم نوین قالب‌تونلی، ارزیابی آسیب‌ﭘﺬیری لرزه‌ای ساختمان‌های دارای نامنظمی جرمی در ارتفاع امری ضروری می‌نماید. در این تحقیق، رفتار لرزه‌ای ساختمان‌های قالب‌تونلی 5 و 10 طبقه با الگوهای مختلف نامنظمی جرمی در ارتفاع در محدوده تغییرشکل‌های غیرخطی مورد مطالعه قرار گرفت. بدین منظور سطوح عملکرد لرزه‌ای ساختمان‌های مورد مطالعه تحت زلزله طرح با استفاده از تحلیل‌های تاریخچه زمانی و بار افزون بررسی شد. برآورد منحنی‌های شکنندگی در سطوح مختلف شدت از دیگر دستاوردهای این تحقیق است. نتایج بیانگر عملکرد مطلوب سیستم ساختمانی مورد مطالعه و تامین سطح عملکرد قابلیت استفاده بی‌وقفه تحت حداکثر زلزله طراحی استاندارد 2800 می‌باشد. به علاوه، مشخص شد که پاسخ مودی ارتعاشی در سیستم متاثر از ارتفاع ساختمان و الگوهای توزیع جرم در ارتفاع نیست. به نظر می‌رسد، بند پنجم از ضوابط ابلاغی مرکز تحقیقات ساختمان و مسکن ایران در خصوص طرح و اجرای ساختمان‌های بتنی با سیستم قالب‌تونلی که بر منظم بودن در ارتفاع تاکید می‌کند، حداقل برای مدل‌ها و الگوهای نامنظمی مورد مطالعه، سختگیرانه و محتاطانه است.}, keywords_fa = {سیستم قالب‌تونلی,سطح عملکرد,نامنظمی جرمی,نامنظمی در ارتفاع,منحنی‌های شکنندگی}, url = {https://www.jsce.ir/article_48946.html}, eprint = {https://www.jsce.ir/article_48946_4ee0b6882813c4aba9287df1bf54a891.pdf} } @article { author = {Kheyroddin, Ali and Sharbatdar, Mohammad Kazem and Ashary, Ali}, title = {Experimental Evaluation of RC Damaged Frames Rehabilitated at Critical Zones with CFRP Composite layers}, journal = {Journal of Structural and Construction Engineering}, volume = {5}, number = {شماره ویژه 4}, pages = {22-35}, year = {2019}, publisher = {Iranian Society of Structural Engineering (ISSE)}, issn = {2476-3977}, eissn = {2538-2616}, doi = {10.22065/jsce.2017.86033.1173}, abstract = {Fiber-reinforced polymer (FRP) composites have been used for structural strengthening in the recent decay and is the appropriate way to increase structural capacity and gaining more popularity among design professionals over conventional strengthening techniques due to its superior mechanical properties and higher tensile strength, stiffness, and durability compared with other techniques. In this paper, the structural behavior of undamaged and damaged reinforced concrete frames strengthened with CFRP composite material was experimentally evaluated. Initially three half-scale reinforcement concrete frames are considered as reference specimens with same beams and columns dimensions and also reinforcement, but different columns stirrup distances 100,200 and 300 mm at the first, second and third specimens respectively. The reference frames were tested under constant axial load and increasing lateral load up to their maximum capacity and failure points, and leaving severe damaged frames. Then, the damaged frames were strengthened with CFRP (Carbon Fiber Reinforced Polymer) composite layers with same arrangement at the critical zones around connections and tested again same as the reference specimens at axial and lateral loadings. The test results indicated that with increasing column stirrup distances of reference specimens, the maximum capacity and ductility and energy absorption were decreased up to 10, 50, and 74%, respectively. And also the maximum capacity and ductility of strengthened specimens were decreased up to 20 and 80% comparing to reference specimens but the energy absorption of strengthened specimens were increased.}, keywords = {RC frame,Rehabilitation,CFR Polymer composite,Ductility,Energy absorption,Maximum Capacity}, title_fa = {ارزیابی آزمایشگاهی قاب های بتن آرمه آسیب دیده تقویت شده در نواحی بحرانی با ورق های کامپوزیتی مسلح پلیمری CFRP}, abstract_fa = {یکی از روش های مفید در مقابله با نیروهای جانبی در تقویت سازه های بتن آرمه، استفاده از FRP می باشد. استفاده از این الیاف در سازه های بتنی به دلیل اجرای سریع و آسان، اقتصادی بودن، مقاوم کردن ساختمان های ضعیف در برابر زلزله و نیز ایجاد کمترین آسیب به سازه، در چند دهه اخیر مورد توجه مهندسین عمران قرار گرفته است. در این مقاله به بررسی آزمایشگاهی رفتار قاب های بتنی آسیب ندیده و دیده تقویت شده با استفاده از ورق های الیافی کربن برای بهبود رفتار سازه ای آن ها پرداخته شده است تا بتوان الگوی رفتاری این سازه ها را مورد بررسی قرار داد. سه نمونه مرجع آزمایشگاهی با مقیاس 1:2 با ابعاد یکسان تیرها و ستون ها و آرماتورگذاری انتخاب شدند و تحت بار قائم ثابت و بارگذاری جانبی افزاینده قرار گرفتند. همه قاب ها دارای فاصله یکسان خاموت ها در تیرها بوده ولی فاصله خاموت ها در ستون های نمونه های یک و دو و سه به ترتیب 100 ، 200، و 300 میلیمتر بودند. پس از اعمال بار و آسیب دیدن کامل قاب های مرجع، با استفاده از لایه های یکسان الیاف مسلح پلیمری کربنی (Carbon Fiber Reinforced Polymer) CFRP در نواحی بحرانی اطراف اتصالات مقاوم سازی شدند و قاب های آسیب دیده تقویت شده مجددا تحت بارگذاری قائم و جانبی قرار گرفتند. نتایج نشان داد که با افزایش فاصله خاموت های نمونه های مرجع، ظرفیت نهایی و شکل پذیری و جذب انرژی به ترتیب تا 10، 50% و 74 درصد کاهش یافت. ظرفیت نهایی و شکل پذیری نمونه های تقویت شده نسبت به نمونه تقویت نشده به ترتیب تا 20، و 80 درصد کاهش یافته ولی جذب انرژی عموما افزایش یافته است.}, keywords_fa = {قاب خمشی بتن آرمه,مقاوم سازی,کامپوزیت مسلح پلیمری CFRP,شکل‌پذیری,جذب انرژی,ظرفیت نهایی}, url = {https://www.jsce.ir/article_49609.html}, eprint = {https://www.jsce.ir/article_49609_4011896a4c331512dc98087bb46b5b90.pdf} } @article { author = {Rahgozar, Navid and sarvghad moghadam, Abdolreza}, title = {Inelastic displacement ratio for rocking buildings subjected to far-field and near-field pulse-like ground motions}, journal = {Journal of Structural and Construction Engineering}, volume = {5}, number = {شماره ویژه 4}, pages = {36-57}, year = {2019}, publisher = {Iranian Society of Structural Engineering (ISSE)}, issn = {2476-3977}, eissn = {2538-2616}, doi = {10.22065/jsce.2017.77217.1070}, abstract = {Self centering rocking buildings are capable of reducing permanent damage and concentrating damage to replaceable energy dissipation devices. This paper aims to calculate inelastic displacement ratio for self centering rocking buildings under far field and near field pulse like ground motions. In this paper, the inelastic displacement ratio, i.e. the ratio of the maximum inelastic displacement to the maximum displacement of the elastic system, for self centering rocking systems are determined using nonlinear dynamic time history analysis. The effects of seismic and modeling parameters on the inelastic displacement demands of self centering rocking buildings are also evaluated. Findings show that the effect of the pulse period of ground motions, predominant period of ground motions, and modelling parameters (i.e. response modification factor, hardening ratio, and energy dissipation ratio) on the inelastic displacement ratio are considerable, while influences of the other parameters such as distance to the fault site, ground motion magnitude, and the soil site are less on the analysis results. Finally, using a two-stage regression on the statistical results, new equations are proposed for estimation of the scaled and unscaled (code base) constant strength spectra of self centering rocking buildings under far field and near field pulse like ground motions.}, keywords = {self-centering rocking system,inelastic displacement ratio,far-field ground motions,near-field ground motions,Nonlinear dynamic analysis}, title_fa = {نسبت تغییرمکان غیرالاستیک سازه‌های دارای حرکت گهواره‌ای در زلزله‌های حوزه دور و نزدیک به گسل پالس‌گونه}, abstract_fa = {سازه های دارای حرکت گهواره‌ ای مرکزگرا توانایی کاهش آسیب ماندگار و تمرکز خسارت در میراگرهای تعویض پذیر را دارند. این مقاله به تعیین نسبت تغییرمکان غیرالاستیک سیستم های برگشت پذیر دارای حرکت گهواره‌ای در معرض زلزله های حوزه دور از گسل و نزدیک به گسل پالس مانند می پردازد. نسبت تغییرمکان غیرالاستیک، یعنی نسبت حداکثر تغییرمکان غیرالاستیک به حداکثر تغییرمکان الاستیک سیستم، با انجام تحلیل های دینامیکی غیرخطی تاریخچه زمانی بدست می آید. همچنین تاثیر پارامترهای لرزه ای و مدل سازی بر پاسخ تغییرمکان غیرالاستیک سازه برگشت پذیر دارای حرکت گهواره‌ای ارزیابی می شود. نتایج مطالعه نشان می دهد، تاثیر پارامترهای دوره تناوب پالس زلزله، دوره تناوب غالب رکوردها، و پارامترهای مدلسازی (ضریب اصلاح پاسخ، سختی پس از تسلیم و نسبت انرژی اتلافی) بر نسبت تغییرمکان غیرالاستیک قابل ملاحظه است، اما پارامترهای دیگر نظیر فاصله سایت تا مرکز گسلش، بزرگای زلزله و نوع سایت تاثیر کمتری بر نتایج تحلیل دارد. در انتها با استفاده از رگراسیون دو مرحله ای نتایج مطالعه آماری، روابطی جدید برای برآورد طیف های با مقاومت ثابت مقیاس نشده (سازگار با آیین نامه) و مقیاس شده برای سیستم های مرکزگرا دارای حرکت گهواره‌ای در معرض زلزله های دور و نزدیک گسل پالس‌گونه ارائه شده است.}, keywords_fa = {سیستم برگشت پذیر دارای حرکت گهواره ای,نسبت تغییرمکان غیرالاستیک,زلزله‌ حوزه دور,زلزله‌ حوزه نزدیک پالس‌گونه,تحلیل دینامیکی غیرخطی}, url = {https://www.jsce.ir/article_50145.html}, eprint = {https://www.jsce.ir/article_50145_11f5ed375605c2bdee921f36a9511a41.pdf} } @article { author = {Ebadi Jamkhaneh, Mehdi and Kafi, Mohammad Ali and Kheyroddin, Ali}, title = {Experimental and numerical investigations of partially encased composite columns under axial load}, journal = {Journal of Structural and Construction Engineering}, volume = {5}, number = {شماره ویژه 4}, pages = {58-72}, year = {2019}, publisher = {Iranian Society of Structural Engineering (ISSE)}, issn = {2476-3977}, eissn = {2538-2616}, doi = {10.22065/jsce.2017.92721.1264}, abstract = {In current international practice, composite construction is gaining importance in industrial buildings and in particular in high-rise buildings. Partially encased composite (PEC) columns are one of the recent developments in composite column. Using composite columns have several advantages such as an increased speed of erection compared to reinforced concrete (RC) columns, a more cost-effective design, smaller cross-section dimensions for similar axial resistance, and a better resistance to fire and local buckling than for steel only columns in compare with traditional RC or steel only columns. One of the proper sections for columns is a cross-sectional shape that can be used in these columns. In this paper, experimental and numerical studies are carried out on three PEC columns under pure compression load. The main difference between the specimens is in the reinforcement details of the concrete. Parameters studied in numerical work, details of reinforcement, failure mode, width to thickness ratio of steel flange and distance and transverse link diameter. The results are presented in the form of axial load-displacement curves. Also, the values of experimental work were compared with the relations between the two European and Canadian regulations, which indicated that the Canadian code was conservative. The results were developed in a numerical section after validation with a laboratory specimens and the load-bearing capacity and deformation were evaluated. The evident buckling pattern in the specimens was the kind of rupture of the welds of the links and the local buckling of the flange plate between the two links. Also, the bigger interval between the two links caused an early local buckling in the specimen.}, keywords = {Partially encased composite column,Load-bearing capacity,Local buckling,Cross section,Transverse link}, title_fa = {بررسی آزمایشگاهی و عددی رفتار ستون های مختلط نیمه مدفون تحت بار محوری}, abstract_fa = {اعضای مختلط فولادی نیمه مدفون در دهه های اخیر مورد توجه در ساخت سازه ها قرار گرفته است. یک عضو با محصورشوندگی نسبی مزایایی از قبیل مقاومت خمشی بالا، حجم قالب بندی پایین، امکان اجرای ساده تر (راحت تر) اتصالات، سهولت مقاوم سازی، افزایش تعداد اتصالات و مقاومت در برابر آتش را داراست. یکی از مقاطع مناسب برای ستون ها، مقطع صلیبی شکل است که می تواند در این ستون ها مورد استفاده قرار گیرد. در این تحقیق، مطالعه آزمایشگاهی و عددی بر روی سه ستون مختلط نیمه مدفون تحت بار فشاری خالص انجام می‌شود. تفاوت اصلی بین نمونه ها در جزدیات مسلح سازی مقطع و بتن است. پارامترهای مورد مطالعه در کار عددی، جزئیات مسلح سازی، مود تسلیم، نسبت عرض به ضخامت بال مقطع فولادی و فاصله و قطر لینک های عرضی است. نتایج در قالب نمودارهای نیرو-تغییرمکان محوری ارائه شدند. همچنین مقادیر حاصل از کار آزمایشگاهی با روابط دو آئین‌نامه اروپا و کانادا مقایسه شد که نشان از دست پایین بودن آئین نامه کانادا داشت. نتایج در بخش عددی، پس از اعتبار سنجی با نمونه ی آزمایشگاهی توسعه داده شد و ظرفیت و شکل پذیری نمونه ها مورد ارزیابی قرار گرفت. مود کمانشی مشهود در نمونه ها از نوع پارگی جوش لینک ها و کمانش موضعی ورق بال بین دو لینک بود. همچنین فاصله ی زیاد دو لینک از یکدیگر باعث بروز کمانش موضعی زودهنگام در نمونه شد.}, keywords_fa = {ستون مختلط نیمه مدفون,ظرفیت باربری,کمانش موضعی,مقطع صلیبی,لینک عرضی}, url = {https://www.jsce.ir/article_50758.html}, eprint = {https://www.jsce.ir/article_50758_e14b7f044dc53e8d773087fdbd12b711.pdf} } @article { author = {Gholhaki, Madjid and Karimi, Mahdi and Pachideh, Ghasem}, title = {Investigation of Subpanel Size Effect on Behavior Factor of Stiffened Steel Plate Shear Wall}, journal = {Journal of Structural and Construction Engineering}, volume = {5}, number = {شماره ویژه 4}, pages = {73-87}, year = {2019}, publisher = {Iranian Society of Structural Engineering (ISSE)}, issn = {2476-3977}, eissn = {2538-2616}, doi = {10.22065/jsce.2017.86522.1198}, abstract = {Steel plate shear wall (SPSW) systems have been used in recent years in highly seismic areas to resist lateral loads. In general, a steel plate shear wall system consists of a steel plate wall, boundary columns, horizental floor beams and optional vertical and horizental stiffener plates. Utilizing stiffener plates causes changing of Steel Plate Shear Wall system behaviour, especially in nonlinear domain. In this paper subpanel size effects have been investigated on such nonlinear behavior. Five cases (one without stiffener and four with stiffener) were considered. A numerical analysis, based on finite element method was performed for each case. These analyses possess a pushover monotonic analysis. Then capacity curvature of system was derived and nonlinear behavior parameters such as “Behaviour Factor” and “Ductility Factor” were calculated by prevailing relationships. Studies show that by reducing of subpanel size, nonlinear characteristics of Steel Plate Shear Wall systems improve considerably. Also some relationships proposed for assessment of nonlinear characteristics of such system. Regarding the structures with high hardness (frequencies greater than about 2 Hz), increase in the behaviour coefficient in negligible, and in general, for this frequency range, it is recommended to use a fixed amount for the behaviour factor ranged from 11 to 13.}, keywords = {steel plate shear wall,Stiffener plate,Subpanel,Ductility,Behavior factor}, title_fa = {مطالعه ی اثر اندازه زیر صفحه ها بر ضریب رفتار دیوارهای برشی فولادی تقویت شده}, abstract_fa = {گسترش استفاده از دیوارهای برشی فولادی بعنوان یکی از انواع سیستم باربر جانبی در طراحی سازه ها و یا مقاوم سازی سازه‌های موجود، موجب افزایش توجه محققان نسبت به بررسی دقیق‌تر رفتار و عملکرد آن بویژه تحت اثر بارهای لرزه‌ای گردیده است. استفاده از سخت کننده فولادی به شکل مناسب یکی از روشهای رایج برای بهبود عملکرد و ارتقاء رفتار این نوع سیستم محسوب می‌گردد. در این مقاله به بررسی اثر اندازه چشمه سخت کننده‌ها بر روی پارامترهای رفتاری غیرخطی این نوع سیستم و بویژه ضریب رفتار سیستم پرداخته شده است. در این تحقیق یک دیوار برشی فولادی بدون سخت‌کننده با چهار حالت دارای سخت‌کننده توسط آنالیزهای عددی مورد مقایسه قرار گرفته است. نتایج بدست آمده با استفاده از روشهای عددی حاکی از آن است که کوچک شدن اندازه زیرصفحات باعث افزایش محسوس شکل پذیری و ضریب رفتار سیستم می‌گردد. در این تحقیق روابط پیشنهادی برای محاسبه ضریب رفتار بر اساس نسبت ابعادی اندازه چشمه سخت کننده‌ها نیز ارائه گردیده است. در خصوص سازه‌ های با سختی زیاد (فرکانس بیشتر از حدود 2 هرتز) افزایش ضریب رفتار ناچیز بوده و بطور کلی برای این محدوده فرکانسی استفاده از مقداری ثابت برای ضریب رفتار در حدود 11 تا 13 پیشنهاد می‌شود.}, keywords_fa = {دیوار برشی فولادی,سخت کننده,زیرصفحه,شکل‌پذیری,ضریب رفتار}, url = {https://www.jsce.ir/article_51241.html}, eprint = {https://www.jsce.ir/article_51241_428917acefb4a3ed30791458ac4ba49a.pdf} } @article { author = {Gholhaki, Madjid and Pachideh, Ghasem and Lashgari, Rahim and Rezayfar, Omid}, title = {Experimental and Numerical Study of Buckling Restrained Bracing Behavior with Combined Steel and Polyamide Sheath}, journal = {Journal of Structural and Construction Engineering}, volume = {5}, number = {شماره ویژه 4}, pages = {88-108}, year = {2019}, publisher = {Iranian Society of Structural Engineering (ISSE)}, issn = {2476-3977}, eissn = {2538-2616}, doi = {10.22065/jsce.2017.86109.1190}, abstract = {One of the most widely used system resisting against lateral loads in the design and retrofit of concrete and steel structures is steel bracing. One of the methods developed by the researchers is the use of confining members to prevent general buckling of bracing and reducing the effects of it. In this bracing system known as "Buckling Restrained Bracing, the axial load is born by bracing core and by using surrounding sheath, its overall buckling can be avoided. In this paper, experimental and numerical study of the effects caused by steel type of core of the distance of core from sheath on buckling restrained bracing was studied. Experimental models consist of six bracings with core of conventional ST37 and ST37-n steel (softened at a temperature of 1000 degrees by O'Neill method), in which the distance of core from sheath is zero, two, and three mm. Experimental results show that the use of softer steel with lower yield stress and with equal thickness in the core reduces bearing capacity and resistance or strength of bracing. However, bracing in smaller displacements started to energy waste. Increasing distance of the core from sheath also reduces bearing capacity and energy dissipation of bracing. In addition, increasing the distance of core from sheath to more than 2 mm causes the loss of symmetry and stability in hysteresis behavior of bracing and distortions resulting from local buckling in the bracing in pressure were intensified. Polyamide filler material had good resistance against pressure from the core and no certain damage was seen in it. Therefore, due to having less specific gravity, it could be a good alternative to concrete and reduce the overall weight of the bracing.}, keywords = {Buckling Restrained Bracing,steel sheath,polyamide sheath,distance of core from sheath,strenght}, title_fa = {مطالعه آزمایشگاهی و عددی رفتار مهاربند کمانش ناپذیر با غلاف ترکیبی فولادی و پلی آمید}, abstract_fa = {یکی از سیستم‌های پرکاربرد مقاوم در برابر بارهای جانبی در طراحی و مقاوم‌سازی سازه‌های بتنی و فولادی‌، مهاربند فولادی است. یکی از روش‌های ابداع شده توسط محققان، استفاده از اعضای محصور کننده برای جلوگیری از کمانش کلی مهاربند و کاهش اثرات ناشی از آن است. در این سیستم مهاربندی که به "مهاربند کمانش‌ناپذیر" موسوم است، بار محوری توسط هسته مهاربند تحمل شده و با استفاده از یک غلاف محصور کننده از کمانش کلی آن جلوگیری می‌شود. در این مقاله مطالعه آزمایشگاهی و عددی اثرات ناشی از نوع فولاد هسته و فاصله هسته از غلاف بر رفتار مهاربند کمانش‌ناپذیر مورد بررسی قرار گرفته است. مدل‌های آزمایشگاهی شامل شش مهاربند با هسته‌ای از جنس فولاد ST37 معمولی و ST37-n (نرم شده در دمای 1000 درجه به روش اونیل) است که در آن‌ها فاصله هسته از غلاف برابر صفر، دو و سه میلی‌متر است. نتایج آزمایشگاهی نشان می دهد که استفاده از فولاد نرم‌تر با تنش تسلیم پایین‌تر و با ضخامت برابر در هسته موجب کاهش ظرفیت باربری و مقاومت مهاربند می گردد. اما مهاربند در تغییرمکان‌های کوچکتری شروع به اتلاف انرژی کرده است. افزایش فاصله هسته از غلاف نیز موجب کاهش ظرفیت باربری و استهلاک انرژی مهاربند می گردد. همچنین افزایش فاصله هسته از غلاف به بیش از 2 میلی‌متر، موجب از بین رفتن تقارن و پایداری رفتار هیسترزیس مهاربند شده و اعوجاج‌های ناشی از کمانش موضعی مهاربند در فشار، شدت بیشتری می یابد. ماده پرکننده پلی‌آمید در برابر فشارهای وارده از طرف هسته مقاومت مناسبی داشته و دچار هیچ‌گونه خرابی خاصی نشده است. بنابراین با توجه به دارا بودن وزن مخصوص کمتر می‌تواند جایگزین مناسبی برای بتن باشد و وزن کلی مهاربند را کاهش دهد.}, keywords_fa = {مهاربند,کمانش ناپذیر,غلاف فولادی,غلاف پلی آمید,فاصله ی هسته}, url = {https://www.jsce.ir/article_51248.html}, eprint = {https://www.jsce.ir/article_51248_a95c0f016a386b196bc22d9ea1077092.pdf} } @article { author = {Sajedi, Fathollah and Jalilifar, Hasan}, title = {Study and comparison of the effect of natural zeolite and silica fume on mechanical properties of recycled aggregates concretes}, journal = {Journal of Structural and Construction Engineering}, volume = {5}, number = {شماره ویژه 4}, pages = {109-126}, year = {2019}, publisher = {Iranian Society of Structural Engineering (ISSE)}, issn = {2476-3977}, eissn = {2538-2616}, doi = {10.22065/jsce.2017.88276.1224}, abstract = {The present study was conducted to compare the effect of natural zeolite (Z) and silica fume (SF) pozzolans on the mechanical properties of recycled aggregates concrete (RAC’s). The RCA’s made with using different levels of recycled coarse aggregates instead of natural coarse aggregates. To improve quality of RCA’s, the introduced pozzolans were replaced with different levels of ordinary Portland cement (OPC). To determine and compare the mechanical properties of concretes, 24 mix designs were made and different tests done as compressive strength at the ages 7, 28 and 91 days, and the tests as splite cylinder tests (SPT), modulus of elasticity and ultra-pulse velocity (UPV) at the age of 28- day. The obtained results generally showed that in duration of 28 days, the usage of silica fume could results in about 40 MPa compressive strength for RCA’s with 100% of recycled coarse aggregates; meanwhile using natural zeolite was not able to give target strength of design. Using 10% of silica fume instead of OPC in RCA’s specially RCA’s having 25% of recycled aggregates caused in the mechanical properties of RCA’s be rarely like those natural aggregate concretes. Although, using 10% of zeolite in concrete could improve some mechanical properties, but the concretes containing silica fume gave superior mechanical properties than those of zeolite.}, keywords = {Recycled aggregates concrete (RAC),Mechanical properties,Silica fume (SF),Natural zeolite (Z),Pozzolan}, title_fa = {بررسی و مقایسه تاثیر زئولیت طبیعی و میکروسیلیس بر رفتار مکانیکی بتن های بازیافتی}, abstract_fa = {تحقیق حاضر به بررسی مقایسه‌ای تاثیر استفاده از پوزولان‌های زئولیت طبیعی و میکروسیلیس بر مشخصات مکانیکی بتن‌های بازیافتی پرداخته است. بتن‌های بازیافتی، متشکل از سطوح مختلف جایگزینی درشت‌دانه‌های بازیافتی بتنی با درشت‌دانه طبیعی هستند. جهت بهبود کیفیت بتن‌های بازیافتی، پوزولان‌های معرفی شده در سطوح مختلفی با سیمان جایگزین شدند. جهت تعیین و مقایسه مشخصات مکانیکی بتن‌ها، 24 طرح اختلاط ساخته شد و آزمایش‌های مقاومت فشاری در سنین 7، 28 و 91 روزه، مقاومت کششی دو نیم‌‌شدن در سن 28 روزه، ضریب ارتجاعی در سن 28 روزه و سرعت امواج فراصوت در سن 28 روزه انجام شدند. نتایج نشان دادند که به طور کلی در بازه 28 روزه، استفاده از میکروسیلیس می‌تواند باعث شود تا بتن‌های 100% بازیافتی به مقاومت مطلوب 40 مگاپاسکالی دست یابند؛ در حالی که استفاده از زئولیت طبیعی نمی‌تواند منجر به کسب مقاومت هدف طراحی گردد. استفاده از سطح جایگزینی 10 درصدی میکروسیلیس به ویژه در بتن‌های حاوی 25% مصالح بازیافتی باعث گردید تا رفتار مکانیکی بتن‌های بازیافتی به میزان چشم‌گیری به بتن‌های معمولی نزدیک گردد؛ هر چند که سطح جایگزینی 10% زئولیت نیز در تامین برخی از خواص مکانیکی بتن‌های بازیافتی مطلوب بوده ولی خواص مکانیکی بتن‌های بازیافتی حاوی این پوزولان به میزان زیادی از ‌ بازیافتی حاوی میکروسیلیس ضعیف‌تر می‌باشد.}, keywords_fa = {بتن بازیافتی,خواص مکانیکی,میکروسیلیس,زئولیت طبیعی,پوزولان}, url = {https://www.jsce.ir/article_51819.html}, eprint = {https://www.jsce.ir/article_51819_33c8f7b252a7cc9d2c839bf5252e0df0.pdf} } @article { author = {Basirat, Shamsa and Omrani, Mohsen and Behforooz, Babak}, title = {Effect of Microsilica Additive on Compressive Strength and Water Absorption of Lightweight Concrete}, journal = {Journal of Structural and Construction Engineering}, volume = {5}, number = {شماره ویژه 4}, pages = {127-139}, year = {2019}, publisher = {Iranian Society of Structural Engineering (ISSE)}, issn = {2476-3977}, eissn = {2538-2616}, doi = {10.22065/jsce.2017.95976.1301}, abstract = {Concerning the issue of the seismicity of Iran and the effect of structure weight on the amount of earthquake load exerted on the structure, there is the need for stylization of structures in order to reduce the costs of designing and repairing structures against earthquakes. It is possible to build structural light-weight concrete by using different additive materials. Microsilica is of the additives of concrete, which is of a significant role in improving concrete characteristics. In this paper, as regards to the positive influence that the additive material puts on the concrete compressive strength, it has been used as a replacement of a part of the cement used in the concrete mix design. Investigation of the compressive strength of light-weight concrete with microsilica contents of 4, 8, and 12 weight percentage of cement at the ages of 28, 118, and 148 days and the water absorption of 90-day samples have been performed through experimental study. It was observed by investigating the compressive strength and the obtained results that using microsilica up to 12% leads to increase compressive strength relative to the control sample. The optimal amount of the used microsilica at all ages is equal to 8% of cement weight. In addition, by increasing of the consumable microsilica up to 12%, the concrete water absorption is reduced as compared to the control sample, and finally causes to reduce the porosity of the light-weight concrete. All the experiments during this study have been performed at the concrete laboratory of the civil engineering faculty of Islamic Azad University, Najaf Abad Branch.}, keywords = {Structural Light-weight Concrete,Microsilica,Compressive strength,water absorption,Additional material}, title_fa = {تأثیر افزودنی میکروسیلیس بر روی مقاومت فشاری و جذب آب بتن سبک سازه‌ای}, abstract_fa = {ببا توجه به مسئله لرزه‌خیزی کشور ایران و تأثیر وزن سازه بر میزان نیروی زلزله وارد بر سازه نیاز به سبک سازی سازه‌ها است تا هزینه-های مربوط به طراحی و ترمیم سازه ها در برابر زلزله کاهش یابد. ساخت بتن سبک سازه‌ای با استفاده از مواد افزودنی مختلف امکان-پذیر است. از جمله افزودنی‌های بتن میکروسیلیس است که نقش موثری در بهبود مشخصات بتن دارد. در این مقاله ماده افزودنی با توجه به تأثیر مثبتی که بر مقاومت فشاری بتن می‌گذارد؛ به عنوان جایگزین قسمتی از سیمان مصرفی در طرح اختلاط بتن استفاده شده است. بررسی مقاومت فشاری بتن سبک با افزودنی میکروسیلیس به میزان 4، 8 و 12 درصد وزنی سیمان، در سن‌های 28، 118 و 148 روز و جذب آب نمونه‌های 90 روزه از طریق مطالعه آزمایشگاهی انجام شده است. با بررسی مقاومت فشاری و نتایج حاصل مشاهده شد که مصرف میکروسیلیس تا 12 درصد باعث افزایش مقاومت فشاری نسبت به طرح شاهد می‌گردد. مقدار بهینه میکروسیلیس مصرفی در تمامی سنین برابر 8 درصد وزنی سیمان می‌باشد. با افزایش مصرف میکروسیلیس تا 12 درصد نیز، جذب آب بتن نسبت بتن شاهد کاهش و در نهایت باعث کاهش تخلخل بتن سبک می‌شود. کلیه آزمایش‌های این مقاله در آزمایشگاه بتن دانشکده عمران دانشگاه آزاد اسلامی واحد نجف آباد انجام شده است.}, keywords_fa = {بتن سبک,میکروسیلیس,مقاومت فشاری,جذب آب,مواد افزودنی}, url = {https://www.jsce.ir/article_51821.html}, eprint = {https://www.jsce.ir/article_51821_e85c4812c7f1d17f4185496373bc37a1.pdf} } @article { author = {Rahman Shokrgozar, Hamed and Ghannadiasl, Amin and omidi, hashem}, title = {Concrete Filled Double Steel Plate Shear Wall Response Modification Factor}, journal = {Journal of Structural and Construction Engineering}, volume = {5}, number = {شماره ویژه 4}, pages = {140-155}, year = {2019}, publisher = {Iranian Society of Structural Engineering (ISSE)}, issn = {2476-3977}, eissn = {2538-2616}, doi = {10.22065/jsce.2017.89253.1232}, abstract = {Composite steel shear wall is a newest seismic resistant system that has a high stiffness, strength and ductility. The main advantages of this structural system are lower thickness and weight, don’t need to reinforcement and its easy implementation procedure with compared to concrete reinforced shear walls. Recently, the behavior of various types of this seismic resistant system has been investigated through numerical or experimental studies. Response modification factor, over-strength factor and deflection amplification factor are the most important parameters for analysis and design of any seismic resistant system. The response modification factor of concrete filled double steel plate shear wall (CFDSPSW) is determined in this paper. For this purpose, an eight-story building with two ratios of wall length to wall heights (1.5 and 2) are designed with CFDSPSW system. To investigation the effect of the concrete core thickness, three different thickness (50, 125, 200mm) is considered. The finite-element model of all cases is developed using ABAQUS software and the combination of nonlinear static pushover; nonlinear incremental dynamic and linear dynamic analyses are used for calculation of the response modification factor. The results are shown that the enhancement in the concrete core thickness lead to increasing ductility and decreasing force reduction factor. The over-strength factor and response modification factor are obtained respectively 1.76 and 6.47 for this seismic resistant structural system.}, keywords = {Concrete filled double steel- plate shear wall,Response modification factor,Over-strength factor,Force reduction factor,Nonlinear Static Pushover Analysis,Nonlinear incremental dynamic analysis,Linear dynamic analysis}, title_fa = {محاسبه ضریب رفتار سیستم های دیوار برشی مرکب با جفت ورق فولادی}, abstract_fa = {یکی از سیستم‌های نوین مقاوم در برابر زلزله سیستم دیوار برشی مرکب فولادی است که دارای سختی، مقاومت و شکل پذیری بسیار بالایی است. مهمترین مزیت این سیستم نسبت به دیوارهای برشی بتن مسلح، ضخامت کمتر، وزن پایینتر، عدم نیاز به آرماتورگذاری و سهولت اجرای آن است. امروزه عملکرد انواع گوناگون این سیستم از طریق مطالعات آزمایشگاهی و عددی تحت تحقیق و بررسی قرار دارد. اما برای تحلیل و طراحی هر سیستم مقاوم در برابر زلزله وجود پارامترهای لرزه ای چون ضریب رفتار، ضریب اضافه مقاومت و ضریب تشدید تغییرمکان بسیار مهم و ضروری است. در این مقاله ضریب رفتار دیوارهای برشی فولادی مرکب با جفت ورق فولادی محاسبه و تعیین گردیده است. بدین منظور ساختمان هشت طبقه ای با سیستم مزبور و همچنین با دو نسبت طول دهانه دیوار به ارتفاع آن (1.5 و 2) طراحی گردیده است. برای بررسی میزان تاثیر ضخامت هسته بتنی، سه ضخامت مختلف دیوارها (50، 125 و 200 میلیمتر) برای هسته بتنی درنظر گرفته شده اند. مدلسازی سازه در دو حالت یک طبقه و هشت طبقه توسط نرم افزار آباکوس انجام گرفته و جهت محاسبه ضریب رفتار روشی ترکیبی متشکل از تحلیل استاتیکی غیرخطی، تحلیل دینامیکی غیرخطی افزایشی و تحلیل دینامیکی خطی پیشنهاد و بکار برده شده است. نتایج بدست آمده نشان داد که افزایش ضخامت هسته بتنی منجر به افزایش شکل پذیری و کاهش ضریب نیرو بر اثر شکل پذیری می گردد. همچنین ضریب اضافه مقاومت و ضریب رفتار حاصل شده برای این سیستم به ترتیب 1.76 و 6.45 حاصل گردیده است.}, keywords_fa = {دیوارهای برشی فولادی مرکب,ضریب رفتار,ضریب اضافه مقاومت,ضریب کاهش نیرو در اثر شکل پذیری,تحلیل استاتیکی غیرخطی,تحلیل دینامیکی افزایشی غیرخطی,تحلیل دینامیکی خطی}, url = {https://www.jsce.ir/article_51822.html}, eprint = {https://www.jsce.ir/article_51822_e2d4aa154bfeae9ee14c38502f36d6a5.pdf} } @article { author = {Hatefi, Seyed Morteza and Heidari, Ali}, title = {Evaluating construction projects based on the risk factors by using an integrated fuzzy AHP and fuzzy VIKOR model}, journal = {Journal of Structural and Construction Engineering}, volume = {5}, number = {شماره ویژه 4}, pages = {156-175}, year = {2019}, publisher = {Iranian Society of Structural Engineering (ISSE)}, issn = {2476-3977}, eissn = {2538-2616}, doi = {10.22065/jsce.2017.89816.1238}, abstract = {Planning and managing the risks is the first step that should be performed at the start of projects and before doing the works. Construction projects start in a complex and dynamic environment and due to the close relation between the parameters of projects and unknown environment, they face with the uncertainties and risks. In this paper, construction projects are evaluated by combining multi criteria decision making methods, i.e., fuzzy AHP and fuzzy VIKOR. The fuzzy concepts are utilized for modelling the existing uncertainty in data. For doing so, first a comprehensive list of risk factors affecting on the success of construction projects is taken from the literature review. They are customized by the experts’ opinions and then the final risk factors are selected. The fuzzy AHP is used to determine the importance of the risk factors. The results of applying fuzzy AHP show that the risks of time and cost have high weights among risk factors. Furthermore, weakness in the construction schedule, the collapse, and the high bidding price are determined as the high importance sub factors of risk. Finally, the proposed model is applied for assessing and prioritizing five construction projects in the area of road construction in Isfahan, Iran.}, keywords = {Construction projects,Risk Management,risk factors,fuzzy AHP,Fuzzy VIKOR}, title_fa = {ارزیابی پروژه های ساخت بر اساس فاکتورهای ریسک با استفاده از مدل یکپارچه فرایند تحلیل سلسله مراتبی فازی و روش ویکور فازی}, abstract_fa = {برنامه‌ریزی برای مقابله با ریسک و مدیریت آن در هر پروژه‌ای از مهم‌ترین قدم‌هایی است که در ابتدای تعریف پروژه و قبل از شروع کار باید به آن پرداخته شود. پروژه‌های ساخت در محیط پیچیده دینامیکی شروع می‌شوند و به دلیل ارتباط تنگاتنگ بین پارامترهای پروژه و محیط ناشناخته بیرونی با عدم قطعیت و ریسک‌های زیادی مواجه می‌باشند. در این مقاله به ارزیابی و اولویت‌بندی پروژه‌های ساخت بر اساس فاکتورهای ریسک با استفاده از تلفیق روش‌های تصمیم‌گیری چندمعیاره فرایند تحلیل سلسله مراتبی و روش ویکور در شرایط فازی پرداخته می‌شود. به دلیل وجود عدم قطعیت‌های موجود در داده‌ها از مفاهیم فازی برای مدل‌سازی عدم قطعیت داده‌ها بهره جسته می‌شود. در این تحقیق، فاکتورهای ریسک تأثیرگذار بر موفقیت پروژه‌های ساخت با استفاده از ادبیات موضوع و نظرات خبرگان استخراج می‌شوند. از روش AHP فازی برای تعیین میزان اهمیت فاکتورهای ریسک و از روش ویکور فازی برای ارزیابی پروژه‌های ساخت بر اساس فاکتورهای ریسک استفاده می‌شود. نتایج حاصل از پیاده‌سازی روش AHP فازی نشان می‌دهد که از بین فاکتورهای اصلی ریسک، ریسک زمان و ریسک هزینه اهمیت بالاتری نسبت به سایر فاکتورهای ریسک دارند. همچنین، ضعف در برنامه زمان‌بندی ساخت‌وساز، فروپاشی (عیب و نقص) ساخت، و قیمت بالای مناقصه به‌عنوان مهم‌ترین زیرفاکتورهای ریسک شناخته شدند. در انتها، از روش پیشنهادی برای ارزیابی و اولویت‌بندی 5 پروژه ساخت در حوزه راه‌سازی در اصفهان استفاده می‌شود.}, keywords_fa = {پروژه های ساخت,مدیریت ریسک,فاکتورهای ریسک,AHP فازی,VIKOR فازی}, url = {https://www.jsce.ir/article_51823.html}, eprint = {https://www.jsce.ir/article_51823_d930044f9f6b44c5f5ac70c792310767.pdf} } @article { author = {Miri, Mahmoud and Vataniouskouii, Ali asghar and Abiri, Iman}, title = {An investigating the effect of using Lumachelle as a substitute of aggrigate in RCC}, journal = {Journal of Structural and Construction Engineering}, volume = {5}, number = {شماره ویژه 4}, pages = {176-192}, year = {2019}, publisher = {Iranian Society of Structural Engineering (ISSE)}, issn = {2476-3977}, eissn = {2538-2616}, doi = {10.22065/jsce.2017.87935.1222}, abstract = {According to lack of sufficient fine aggregate in some coastal area, using of other aggregate material are advisable. In this experimental study use of Lumachelle as a substitute of fine aggregates and replacement of lime and pozzolan as a part of cement are investigated on roller compacted concrete (RCC). RCC samples carried out and cured according to the related standard and compressive strength, splitting tensile strength, permeability and water absorption are examined. Totally, 9 different RCC mixtures include control mixture, 4 different mixtures include lime ( 5%, 10%, 15% and 20% of cement weight) were used as partial replacement of cement, and 2 different mixtures include 10% and 20% of pozzolan , by cement weight, as partial replacement of cement, were tested. Based on the results, among 5, 10, 15 and 20% of the lime used in this study, the replacement of 5% lime lead 3% increase in compressive strength and 7 % increase of tensile strength and it could be advisable for using in RCC. Moreover, the use of 20% substitutive Taftan pozzolan in RCC mix design decreases 24% of compressive strength and 11% of tensile strength in the short time. Besides, it improves resistance to get equal resistance with control sample in long-term that lead in 22% decrease depth penetration and 5% decrease in water absorption compared to control sample. Therefore use of 15 to 20% of pozzolan are also advisable according to the obtained results.}, keywords = {RCC,Lumachelle,Taftan Pozollan,lime,Compression strength}, title_fa = {بررسی امکان استفاده از لوماشل به عنوان جایگزین مصالح سنگی در ساخت بتن غلتکی}, abstract_fa = {با توجه به محدود بودن منابع سنگی مناسب در مناطق جنوبی کشور و حاشیه دریای عمان، در این مطالعه آزمایشگاهی، امکان استفاده از لوماشل (کپراک) که به فراوانی در سواحل خلیج فارس و دریای عمان وجود دارد، به‌عنوان جایگزین بخشی از مصالح ریزدانه در ساخت بتن غلتکی مورد بررسی قرار گرفته است. بعلاوه تأثیر جایگزینی پوزولان تفتان و آهک زنده بجای مصالح سیمانی بر مقاومت فشاری، مقاومت کششی دونیم شدگی، نفوذپذیری و جذب آب نیز بررسی شده است. در مجموع 9طرح اختلاط مختلف شامل ماسه، لوماشل، و ماسه و لوماشل به عنوان ریز دانه و آهک با درصدهای مختلف 5%، 10%، 15% و 20% و پوزولان تفتان به میزان 10% و 20% وزنی سیمان، ساخته شده و تحت آزمایش قرار گرفته اند. بر اساس نتایج بدست آمده، از میان طرح های اختلاط صورت گرفته، بهترین عملکرد در آزمایشات مقاومت فشاری و کششی در نمونه های حاوی 5 % آهک، در آزمایش نفوذ آب نمونه های حاوی 20 % پوزولان و در آزمایش جذب آب نمونه های ساخته شده با ریزدانه ماسه حاصل شد. نتایج آزمایشات مختلف نشان داد که بطور کلی امکان استفاده از لوماشل به عنوان مصالح ریز دانه در ساخت بتن غلتکی وجود دارد و این امکان می تواند کمک موثری به اقتصاد طرحهای اجرایی در این منطقه باشد. علاوه بر آن استفاده از 15 الی 20% پوزولان به عنوان جایگزین مصالح سیمانی قابل توصیه است.}, keywords_fa = {بتن غلتکی,لوماشل,پوزولان تفتان,آهک,مقاومت فشاری}, url = {https://www.jsce.ir/article_51824.html}, eprint = {https://www.jsce.ir/article_51824_91c18eec08fd912ad7bf96f2c3450096.pdf} } @article { author = {Darvishan, Ehsan}, title = {Low cost health monitoring of cable stayed bridges using synchrosqueezed wavelet transform and nonlinear principal component analysis}, journal = {Journal of Structural and Construction Engineering}, volume = {5}, number = {شماره ویژه 4}, pages = {193-216}, year = {2019}, publisher = {Iranian Society of Structural Engineering (ISSE)}, issn = {2476-3977}, eissn = {2538-2616}, doi = {10.22065/jsce.2017.94398.1280}, abstract = {Today, health monitoring of structures has been standardized in many countries. Such systems for large and complex structures are equipped and include numerous sensors. Therefore, they are not yet practical in our country due to large final expenses. The main purpose of this paper is to introduce a low-cost health monitoring algorithm for structures based on signal processing. Accordingly, only three sensors are utilized to detect damage. Since the accuracy of signal processing method can affect the results of damage detection, in the first part of the paper, five signal processing methods are investigated. Among these procedures two methods are older and have widely used in damage detection. The three others are more recent and are fully investigated in civil engineering. In the second part, a new damage detection method is proposed. This method is a combination of signal processing methods by synchrosqeezed wavelet transform, clustering, and regression with autoassociative artificial neural networks. For this reason, data from Yonghe bridge is utilized which is recorded based on real vibration of the bridge. Results show that the proposed signal processing method is capable to effectively extract signal features. Also the damage detection method is capable to detect damage with acceptable accuracy}, keywords = {health monitoring,Damage detection,Damage index,Yonghe bridge,signal proceesing}, title_fa = {پایش سلامت ارزان قیمت پل های کابلی با استفاده از تبدیل موجک فشرده و آنالیز مولفه های اصلی غیرخطی}, abstract_fa = {امروزه پایش سلامت سازه ها در بسیاری از کشورها به صورت استاندارد درآمده است. سیستمهای پایش سلامت برای سازه های بزرگ و پراهمیت سیستمهایی مجهز و شامل تعداد زیادی سنسور می باشند. لذا استفاده از آنها به علت قیمت بالا هنوز در کشور ما رایج نشده است. هدف اصلی این پژوهش ارائه یک روش ارزان قیمت پایش سلامت سازه ها بر مبنای پردازش سیگنال است. بر این اساس تنها از 3 سنسور جهت شناسایی خسارت سازه استفاده شده است. از آنجا که دقت روش پردازش سیگنال تاثیر بسزایی بر دقت روش ارائه شده خواهد داشت، در بخش اول پنج روش پردازش سیگنال مورد بررسی قرار گرفته اند. از میان این روشها دو روش نسبت به سایرین دارای قدمت بیشتری می باشند و کاربردهای فراوانی در شناسایی خسارت پیدا کرده اند و سه روش دیگر به تازگی معرفی شده اندو هنوز در مهندسی عمران زیاد مورد بررسی قرار نگرفت اند. در بخش دوم یک روش شناسایی خسارت نوین ارائه شده است. این روش ترکیبی از روشهای پردازش سیگنال به روش تبدیل موجک فشرده، خوشه بندی داده ها و رگرسیون گیری به روش شبکه های عصبی وابسته خودکار است. برای این کار از داده های پل مرجع یونگ استفاده شده است که داده های آن بر اساس ارتعاش واقعی پل ثبت شده اند. نتایج نشان می دهد روش پردازش سیگنال ارائه شده دارای دقت کافی جهت شناسایی خسارت را دارا می باشد.}, keywords_fa = {پایش سلامت سازه,شناسایی خسارت,اندیس خسارت,پل یونگ,پردازش سیگنال}, url = {https://www.jsce.ir/article_51826.html}, eprint = {https://www.jsce.ir/article_51826_0d9fd4377fc2fbfb50675fcc91bd44fe.pdf} } @article { author = {khorasani, fereshteh and gerami, mohsen and kheyroddin, ali}, title = {Comparison between the behavior of RCS and Concrete Moment Frames under Near Fault Earthquakes}, journal = {Journal of Structural and Construction Engineering}, volume = {5}, number = {شماره ویژه 4}, pages = {217-234}, year = {2019}, publisher = {Iranian Society of Structural Engineering (ISSE)}, issn = {2476-3977}, eissn = {2538-2616}, doi = {10.22065/jsce.2017.69420.1014}, abstract = {The composite RCS moment resisting frame, includes concrete columns and steel beams, it has some advantages in comparison to ordinary steel and concrete moment resisting frames. Previous studies have shown that these systems, in case of preserving sufficient strength and needed ductility in seismic condition, could be effective in design and construction. In the previous research on these structures, studies were made on the frame and RCS connections but there has not been any study on the seismic assessment of the RCS structure with time history and for the near fault earthquakes considering the effect of span length, for adopting this type of structure. Investigating the structure behavior under near the fault earthquake, due to the special nature and characteristics of these earthquakes in comparison to the far fault earthquakes seems to be essential. For this purpose 5 composite RCS intermediate moment resisting frames with 4, 7, 10, 15 and 20 stories and 5 spans were designed and then nonlinear dynamic analysis was performed on the structures using the OpenSees software. The obtained results in this research show that with increase in the number of stories the displacement of composite structure decreases with respect to the steel structure. The difference due to near and far fault earthquakes in calculation of stories displacement and drift in steel structures is far lower with respect to this difference in composite structures. This shows that effectiveness of near fault records on composite structures is more than the ordinary steel structures. Increase in the span length together with increase in the structure height would diminish the criticality of near fault record concerning the displacement of a composite structure which its columns have been made similar to the steel structure.}, keywords = {Composite moment frame (RCS),Near fault earthquake,Far fault earthquake,Nonlinear dynamic analysis,Steel moment frame,concrete column}, title_fa = {مقایسه رفتار قاب‌‌های خمشی مرکب (RCS) و فولادی تحت زلزله‌های حوزه نزدیک گسل}, abstract_fa = {بررسی رفتار سازه تحت زلزله ‌های حوزه نزدیک به علت ماهیت ویژه این زمین‌لرزه‌ ها در مقایسه با زلزله ‌های دور از گسل امری ضروری به نظر می ‌رسد‌. در این پژوهش به بررسی نیاز ‌لرزه ‌ای سازه‌ های مرکب RCS و فولادی تحت زلزله‌های حوزه نزدیک گسل در مقایسه با زلزله‌های حوزه دور پرداخته شده است‌. به همین منظور تعداد 5 قاب خمشی مرکب RCS و فولادی با شکل‌پذیری متوسط و در طبقات 4‌، 7‌، 10‌، 15 و 20 و 5 دهانه طراحی شد و سپس تحلیل‌های دینامیکی توسط نرم افزار OpenSees بر روی سازه‌ها انجام شده است‌. نتایج بدست آمده در این پژوهش نشان می‌دهد که هر چه تعداد طبقات بیشتر می شود جابجایی سازه مرکب از سازه فولادی کمتر می شود. اختلاف ناشی از رکوردهای نزدیک و دور از گسل در محاسبه جابجایی و دریفت طبقات در سازه‌های فولادی به مراتب کمتر از این اختلاف در سازه های مرکب است. که نشان می دهد اثربخشی رکورد های نزدیک گسل بر سازه های مرکب بیشتر از سازه های معمول فولادی ست. افزایش دهانه به همراه افزایش ارتفاع سازه، بحرانی بودن رکورد نزدیک گسل بر جابجایی سازه مرکبی که تیرهایش شبیه سازه فولادی شده، را از بین می برد.}, keywords_fa = {قاب خمشی مرکب (RCS),زلزله‌ نزدیک گسل‌,زلزله دور از گسل,تحلیل دینامیکی غیرخطی,قاب خمشی فولادی,اثر ستون بتنی}, url = {https://www.jsce.ir/article_46867.html}, eprint = {https://www.jsce.ir/article_46867_587199066367d47ddd038b2ff686259c.pdf} }