[1] Li Q.S., Fang J.Q., Jeary A.P.,Wong C.K., and Liu D.K. (2000), “Evaluation of wind effects on a super tall building based on full scale measurements”, Earthquake Engineering Structural Dynamics, 29(12), 1845-1862.
[2] Li Q.S., Xiao Y.Q.,Wong C.K., and Jeary A.P., (2004), “Field measurements of typhoon effects on a super tall building”, Engineering Structures, 26, 233-244.
[3] Li Q.S., Yang K., Wong C.K., and Jeary A.P. (2003), “The effect of amplitude-dependent damping on wind-inducedvibrations of s super tall building”, Journal of Wind Engineering and Industrial aerodynamics, 91, 1175-1198.
[4] Simiu, E., (2011), “Design of Buildings for Wind a Guide for ASCE 7-10 Standard Users and Designers of Special Structures”, second ed. John Wiley & Sons, New Jersey, USA.
[5] Solari G. (1985), “Mathematical model to predict 3-D wind loading on buildings”, Journal of Engineering Mechanics, ASCE, 111(2), 254-275, 1985.
[6] Vickery B.J. and Clarke A.W. (1972), “Lift or across-wind response of tapered stacks”, Journal of the Structural Division, 98, 1-20.
[7] Vickery B.J. and Basu R.J. (1983), “Across-wind vibrations of structures of circular cross-section. Part I. development of a mathematical model for two-dimensional conditions”, Journal of Wind Engineering and Industrial Aerodynamics, 12, 49-73.
[8] Vickery B.J. and Basu R.I. (1984), “The response of reinforced concrete structures to vortex shedding”, Journal of Structural Engineering, 6, 324-333.
[9] Menon D. and Rao S. (1997), “Uncertainties in codal ecommendations for across-wind load analysis of R/C chimneys”, Journal of Wind Engineering and Industrial Aerodynamics, 72, 455-468.
[10] Arunachalam S. (2014), “A method for prediction of across-wind response of tall circular concrete chimneys”, Journal of Wind and Engineering, 11(1), 23–39.
[11] Arunachalam S., Lakshmanan N. (2015), “Across-wind response of tall circular chimneys to vortex shedding”, Journal of Wind Engineering and Industrial Aerodynamics, 145, 187–195.
[12] Eimani
K. H., Khodaie N. (2017), “Parametric study of the along-wind and across-wind responses of tall RC chimneys using the frequency domain analysis”, Journal of Structural and Construction Engineering (JSCE), 4(2), 148-160.
[13] Matsumoto T. (1986), “On the Across-wind Oscillation Of Tall Buildings”, Journal of Wind Engineering and Industrial Aerodynamics, 24, 69-85.
[14] Young K., Ki Y., Jang Y. (2004), “Across and along-wind responses of tall building”, Journal of Central of South University of technology, 21, 4404−4408.
[15] Khodaie N. (2019), “Evaluation of modal contribution to the wind‑induced responses of tall buildings”, Asian Journal of Civil Engineering, 20(6), 837-846.
[16] Young K, Ki Y., Nag K. (2008), “Across-wind responses of an aeroelastic tapered tall building”, Journal of Wind Engineering and Industrial Aerodynamics, 96, 1307–1319.
[17] Ming G. & Yong Q. (2011), “Across-wind loads and effects of super-tall buildings and structures”, Science China Press, 54(10), 2531–2541.
[18] Liang S., Li Q. S., Zou L., Wu J. R. (2005), “Simplified formulas for evaluation of across-wind dynamic responses of rectangular tall buildings”, Wind and Structures, 8(3), 197-212.
[19] Chen X. (2013), “Estimation of stochastic crosswind response of wind-excited tall buildings with nonlinear aerodynamic damping”, Engineering Structures, 56, 766–778.
[20] Kareem A. (1982), “Acrosswind response of buildings”, Journal of structural division, ASCE, 108, 869–887.
[21] Kareem A. (1984), “Model for predicting the acrosswind response of buildings”, Engineering Structures, 6, 136-141.
[22] Kwok K. C. S. (1982), “Crosswind response of tall buildings”, Engineering Structures, 4, 258-262.
[23] Cheng C.M., Lu P.C., Chen R.H. (1992), “Wind loads on square cylinder in homogeneous turbulent flows”, Journal of Wind Engineering and Industrial Aerodynamics, 41–4, 739–749.
[24] Choi H., Kanda J. (1993), “Proposed formulae for the power spectral densities of fluctuating lift and torque on rectangular 3-D cylinders”, Journal of Wind Engineering and Industrial Aerodynamics. 46–47, 507–516.
[25] Lianga S., Liu S., Li Q.S., Zhang L., Gu M. (2002), “Mathematical model of acrosswind dynamic loads on rectangular tall buildings”, Journal of Wind Engineering and Industrial Aerodynamics, 90, 1757–1770.
[26] Gu M., Quan Y. (2004), “Across-wind loads of typical tall buildings”, Journal of Wind Engineering and Industrial Aerodynamics, 92, 1147–1165.
[27] Simiu E. and R. Scanlan H. (1996), Wind effects on structures: fundamentals and applications to design citation, 3rd edition, John Wiley & Sons, New York, USA, (1996).
[28] National Building Code Of Canada (NBC 2015), National Research Council Of Canada (NRC), Ottawa, Canada.
[29] Eimani, H., Khodaie, N., (2014), “Parametric Study on the Gust Loading factor (GLF) of Along-Wind Loads on Tall Buildings”, 15th Civil engineering students conference, Urmia, Iran.
[30] Kareem A. (1996), “Damping in structures: its evaluation and treatment of uncertainty”, Journal of Wind Engineering and Industrial Aerodynamics, 59, 131-157.
[31] Eimani, H., Khodaie, N., (2018), “Wind-induced vibration control of super-tall buildings using a new combined structural system”, J. Wind Eng. Ind. Aerod. 172, 256–266.